Local Configurations
143
Figure 5-131
Configure the settings for the User event. See Table 5-43.
Step 2
Parameter
Description
Event Type
In the
Event Type
list, select
Illegal Login
.
Enable
Enable the user error detection function.
If you do not enable this function, there will be no limit for wrong
password entry and the account cannot be locked because of the
wrong password.
Attempt(s)
Set the maximum number of allowable wrong password entries. The
account will be locked after your entries exceed the maximum number.
Lock Time
Set how long the account is locked for. The value ranges from 1 minute
to 60 minutes.
Alarm Out
Click
Setting
to display setting interface.
General Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
External Alarm: Enable alarm activation through the connected
alarm box.
Wireless Siren: Enable alarm activation through devices
connected by USB gateway or camera gateway.
Latch
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 10 seconds to 300
seconds, and the default value is 10 seconds.