Main Function Description
46
Figure 5-9 Counter and Timer Control
Sheet 5-10 Counter and Timer Control - Parameter Explanation
Parameter
Explanation
CounterSelector
Selects the counter which needs to configure
:
Counter0 or Counter1.
If Counter0 is selected
,
CounterEventSource displays FrameTrigger.
If Counter1 is selected
,
CounterEventSource displays FrameStart.
CounterResetSource
Selects the signal source to reset the counter
:
non-reset Off
、
software signal
reset SoftwareSignal0 and hardware signal reset Line1.
CounterEventSource
Select the events that will be the source to increment the Counter
:
FrameTrigger/FrameStart.
CounterReset
The selected counter used for software reset.
TimerSelector
Selects the counter needs to configure. The default is Timer0.
TimerTriggerSource
Selects the trigger source of the start timer. The default is ExposureStart.
TimerTriggerActivation
Selects the trigger mode of the start timer: RisingEdge, FallingEdge or
AnyEdge.
TimerDelay
Sets start timer delay when receiving the trigger.
(μ
s
)
TimerDuration
Sets the duration of the timing pulse.
(μ
s
)
5.10
ISPControl
In this property, you can adjust the image sharpness, brightness, saturation, contrast and so on, as shown
in Figure 5-10; please refer to Sheet 5-11 for detailed parameter settings.
Hue and saturation are only available for the color camera.