![Daher TBM 930 Pilot'S Information Manual Download Page 195](http://html.mh-extra.com/html/daher/tbm-930/tbm-930_pilots-information-manual_499728195.webp)
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 0
Page 3.11.3
INERT SEP FAIL
Symptoms :
-
INERT SEP ON
does not appear within 50 seconds following INERT
SEP switch setting ON,
-
inertial separator is not retracted after 50 seconds following INERT SEP
switch setting OFF,
-
INERT DE ICE breaker triggered.
►
Leave icing conditions as soon as possible
◄
►
Fly the airplane
◄
End of procedure.