Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 2
Page 3.3.6
Engine regulation discrepancy, power loss,
throttle control loss
2/3
►
Continuing
▲
CAUTION
▲
When MAN OVRD control is used, the available power may not be
sufficient to ensure a go-around in landing configuration, particularly if
the weight is near the maximum weight.
▲
►
Do not perform a go around
◄
►
Do not use the reverse
◄
9 -
Land normally.
10 -
Brakes
As required
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End of procedure
■
If minimum power obtained is excessive :
11 -
Airspeed
Reduce below 178 KIAS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
By setting nose-up attitude
12 -
INERT SEP switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If ITT > 840°C :
13 -
INERT SEP switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 -
LANDING GEAR lever
DN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 -
FLAPS lever
TO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 -
Long final or ILS approach
Establish
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
At IAS < 178 KIAS
Continue
►