![Daher TBM 930 Pilot'S Information Manual Download Page 171](http://html.mh-extra.com/html/daher/tbm-930/tbm-930_pilots-information-manual_499728171.webp)
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 5
Page 3.9.5
and
2/3
MAIN GEN
LOW VOLTAGE
►
Continuing
9 -
GENERATOR selector
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If altitude is > 10000 ft :
10 -
OXYGEN switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If VMC and non-icing conditions are possible :
11 -
ESS BUS TIE switch
EMER
. . . . . . . . . . . . . . . . . . . . . . . .
The battery supplies only the ESS BUS and
BATT BUS in this configuration.
►
Land as soon as possible
◄
If use of other than essential systems is required :
12 -
ESS BUS TIE switch
NORM
. . . . . . . . . . . . . . . . . .
End of procedure
■
If VMC and non-icing conditions are not possible :
13 -
Manually disconnect systems as follows :
Breakers :
-
PFD 2
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
ADC 2
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
TAS
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
DATA LINK
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
XPDR 2
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switches :
-
AIRFRAME DE ICE
OFF
. . . . . . . . . . . . . . . . . . . . . .
-
ICE LIGHT
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
PROP DE ICE
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . .
-
WINDSHIELD
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Continue
►
PIM - DO NOT USE FOR FLIGHT OPERATIONS