Error Code
Test program
-
>
At nay time, if overflow pressure switch act and keep for longer than 2 seconds, the E4 will com on.
When E4 happens, the appliance will activate drain pump and cut all the other loads immediately. At the same
time, the buzzer will alarm for 30 seconds and INTENSIVE and ECO program LEDs will flicker simultaneously
and quickly. Then, drain pump will run till the water level pressure switch reset and continue draining for 60
seconds.
Then appliance will detect repeatedly whether water level pressure switch act or not. If it act, run the drain
pump until the pressure switch reset.
E4 Overflow
Once open-circuit failure of thermistor is detected by controller, the appliance will activate the drain pump and
cut all the other loads. At the same time, the buzzer will alarm for 30 seconds and INTENSIVE and RAPID
program LEDs will flicker simultaneously and quickly. Then, drain pump will run till the pressure switch reset
and continue draining for 60 seconds.
E6 Open-circuit failure of thermistor
Once short-circuit failure of thermistor is detected by controller, the appliance will activate the drain pump and
cut all the other loads. At the same time, the buzzer will alarm for 30 seconds and ECO and RAPID program will
flicker simultaneously and quickly. Then, drain pump will run till the pressure switch reset and continue
draining for 60 seconds.
E7 Short-circuit failure of thermistor
49
Flickering
Flickering
Flickering
Priority level of E4 is the highest. E4 operation is valid after other error
operations have done. When E4 operation has done, all the others are invalid.
Caution:
Summary of Contents for EGSP-130E
Page 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Page 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Page 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Page 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Page 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Page 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Page 22: ...21 Exploded view Function Description EGSP 90E ...
Page 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Page 28: ...27 EGSP 9E Exploded view Function Description ...