The defeat point
1. The heater coil is broken, so the heater cannot work. It will cause the E3
error.
2. The thermostat is active, so the heater cannot work. It will cause the E3
error.
3. The connector is loose, so the heater cannot work. It will cause the E3 error.
Heater
Theory of parts
-
>
B
View
ottom
The work principle
Technical data
Location of Heater
pressure switch
Nominal voltage
230VAC
Rating power
1800W
Resistance
29.265 1.463
Ω
Thermastat1
98
℃
Thermastat2
229
℃
39