E2 tree
Inspection
-
>
If the problem has not been solved through all the inspection mentioned
above, maybe the PCB has a malfunction. So, replace PCB and test again.
51
E2 code
Longer drain time
Some water
Check whether the Drain
Pump circuit is correct or
not. (mentioned in section
4)
solve the problem
Not
No water
Is there any
water in the Tub?
Reconnect the wire of
Drain Pump circuit and
check again
OK
Still wrong
Replace the Drain
pump to solve
problem
Make a check of Drain
Hose
solve the problem
Drain Hose is blocked
or kinked
OK
Failure
Failure
When there is no water in the
tub, check whether Pressure
Switch(83/63) circuit is open or
not, which control water inlet.
Reconnect the wire of
Pressure Switch circuit
and check again
OK
Still wrong
Replace the
Pressure Switch to
solve problem
Open
solve the problem
Summary of Contents for EGSP-130E
Page 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Page 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Page 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Page 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Page 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Page 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Page 22: ...21 Exploded view Function Description EGSP 90E ...
Page 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Page 28: ...27 EGSP 9E Exploded view Function Description ...