E1 tree
Inspection
-
>
If the problem has not been solved
through all the inspection mentioned
above, maybe the PCB has a
malfunction. So, replace PCB and test
again.
50
E1 code
Longer inlet time
Make a check of Tap
No water
Not open Open it to solve the
problem
Opened
Check whether the Inlet
Valve circuit is correct or
not. (mentioned in section
4)
solve the problem
Not
Correct
Make a check of the
Hydraulic pressure.
(0.04-1.0MPa is ok)
Little water
Give advice to
consumer
Lower
Make a check of
Drain Hose
OK
Is there any
water in the Tub?
Reconnect the wire of
Inlet Valve circuit and
check again
OK
Still wrong
Replace the Inlet
Valve to solve
problem
Check whether the
Pressure Switch(83/63)
circuit is correct or not.
Make a check of Inlet
Hose
solve the problem
Inlet Hose is blocked or
kinked
OK
Failure
Failure
Reconnect the wire of
Pressure Switch circuit
and check again
Not
solve the problem
OK
Replace the
Pressure switch to
solve problem
Still wrong
Make a check of inlet
hose of AQUASTOP,
(only for the dishwasher
with AQUASTOP device)
Replace it to solve
the problem
Failure
Hang correctly to
solve the problem
Wrong
Summary of Contents for EGSP-130E
Page 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Page 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Page 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Page 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Page 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Page 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Page 22: ...21 Exploded view Function Description EGSP 90E ...
Page 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Page 28: ...27 EGSP 9E Exploded view Function Description ...