Error Code
Test program
-
>
If the inlet valve has been opened for 4 minutes but the water level pressure switch hasn
’
t
act, E1 will come on.
When E1 happens, the appliance will active drain pump and cut all the other loads immediately. At the same
time, the buzzer will alarm for 30 seconds and INTENSIVE program LED will fliker quickly. Then, drain pump
will run till the pressure switch reset and continue draining for 60 seconds.
When the supplementary water inlet time is longer than 4 minutes, E1 also comes on.
E1 Longer inlet time
When the supplementary water inlet time is longer than 4 minutes, E1 also comes on.
Flickering
If the heating element has been working for 60 minutes but the water temperature hasn
’
t reached the proper
value detected by NTC. E3 will come on.
When E3 happens, the buzzer will alarm for 30 seconds and RAPID program LED will flicker quickly. Then,
drain pump will run till the pressure switch reset and continue draining for 60 seconds.
E3 Longer heating time
Caution: during washing program, if appliance has detected NTC failure after heating
element starting work, the program will jump to next step after heating 10 minutes. If there
is no NTC failure detected and water temperature hasn
’
t reached the desired value, the
program will jump to next step after heating 20 minutes.
48
If the drain pump has been running for 4 minutes but the water level pressure switch hasn
’
t reset, E2 will
come on.
When E2 happens, drain pump will keep working for 2 minutesand appliance will cut all the other loads
immediately. At the same time, the buzzer will alarm for 30 seconds and ECO program LED will flicker
quickly.
E2 Longer drain time
Flickering
Flickering
Summary of Contents for EGSP-130E
Page 4: ...Installation instructions 2 Models EGSP 130E EGSP 13E EGSP 90E EGSP 9E 3 ...
Page 9: ...Exploded view Function Description 8 EGSP 130E 2006 ...
Page 10: ...Exploded view Function Description 9 EGSP 130E 3013 3018 3017 3014 ...
Page 15: ...Exploded view Function Description 14 EGSP 13E 2006 ...
Page 16: ...Exploded view Function Description 15 EGSP 13E 3013 3018 3017 3014 ...
Page 20: ...19 Exploded view Function Description EGSP 90E 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 21: ...20 Exploded view Function Description EGSP 90E 2006 ...
Page 22: ...21 Exploded view Function Description EGSP 90E ...
Page 26: ...25 EGSP 9E Exploded view Function Description 1115 1117 1114 1113 1116 1074 a 1023 ...
Page 27: ...26 EGSP 9E Exploded view Function Description 2006 ...
Page 28: ...27 EGSP 9E Exploded view Function Description ...