Charging System/Battery
Battery
Removal
●
Remove the floor panel mat.
●
Loosen the 2 battery cover setting bolts.
●
Remove the battery cover.
Charging Status (Open Voltage) Inspection
●
Remove the battery terminal from the battery.
Check the battery terminal voltage.
Fully charged: 13.0-13.2V
Under charged: Not to exceed 12.3V
NOTE
Charging System Inspection
Leakage Test
●
Turn off the main switch, and remove the earth
cable from the battery. Connect an ampere meter
between the battery terminal and the earth cable,
and check current when the main switch is
turned off.
NOTE
Leakage current: Not to exceed 1mA
15-3
•
Use a PVA multi-tester to check the status of
charging.
•
Use an ampere meter while sequentially
changing its measuring range from large to
small. If the current level greater than the
measuring limit is measured, the ampere meter
fuse may be cut.
•
Do not turn on the main switch while current is
being measured.
Battery cover
Summary of Contents for NS125DLX
Page 1: ...SERVICE MANUAL...
Page 4: ...Service Information 1 2 Identification Numbers Frame serial number Engine serial number...
Page 22: ...MEMO...
Page 43: ...MEMO...
Page 44: ...Fuel System 5 0 Fuel tank Fuel strainer Fuel pump Carburetor...
Page 54: ...MEMO...
Page 58: ...L Crank Case Cover Kick Starter Continuously Variable Transmission 7 0 L crank case cover...
Page 76: ...Generator Starter Clutch 8 0...
Page 107: ...MEMO...
Page 108: ...Transmission Crankshaft Crank Case 11 0 R Crank Case Crankshaft L Crank Case...
Page 154: ...MEMO...
Page 168: ...MEMO...
Page 172: ...MEMO...
Page 180: ...MEMO...
Page 182: ...MEMO...
Page 190: ...2001 4 PRINTED 2001 4 PUBLICATION SERVICE MANUAL NO COPY...