background image

Contents

Before You Begin 

3

3

Important

 Notes

Customer-Assurance Information

Important Safety Instructions

 

4

4

Related Equipment Safety

Installation Safety

I

nstallation Requirement

6

1

2

1

2

1

2

1

3

13

14

16

17

18

19

2

2

22

2

3

2

4

26

26

27

Checklist

Prepar

ing

 to Install the Hood 

Installation Planning

Hood 

Specificat

ions

Electrical/Ductwork Connections

Overall Hood Dimensions

Cabinet Layout Dimensions

Installation Instructions

Meeting Electrical Codes

Preparation and Setup 

Installing the Electrical Source

Meeting Installation Requirements

Planning the Ductwork 

Planning the Mounting Location

Marking the 

Exhaust-Duct 

Centerlines 

Installing the Support Brackets

Rotati

ng the Blowers for 

Rear Exhaust

Assembling the Filters 

Using the 

Optional 

Dual-to-Single Transition Kit #AHT10 

Hanging the Hood

Hardwiring the Hood 

Inserting Light Bulbs 

Verifying 

Proper Function

 

Wiring Diagram

3

4

6

6

7

8

9

10

11

2

 

English

Summary of Contents for DHD30M967

Page 1: ...Installation Instructions Part No 110452 Rev E Modernist Range Hood DHD30M967 DHD36M987 DHD48M987 ...

Page 2: ...rall Hood Dimensions Cabinet Layout Dimensions Installation Instructions Meeting Electrical Codes Preparation and Setup Installing the Electrical Source Meeting Installation Requirements Planning the Ductwork Planning the Mounting Location Marking the Exhaust Duct Centerlines Installing the Support Brackets Rotating the Blowers for Rear Exhaust Assembling the Filters Using the Optional Dual to Sin...

Page 3: ...nce Information To resolve questions and installation issues contact your Dacor dealer or Dacor Customer Assurance Before calling have the hood s model and serial numbers available See the data label inside the hood above the filters on the chassis rear wall Phone 800 793 0093 x2813 US Canada Hours of Operation Mon Fri 5 00 a m to 5 00 p m Pacific Time Website www dacor com customer care contact u...

Page 4: ...o not understand WARNING To reduce risk of property damage fire personal injury and death Do not store or use combustible material e g gas alcohol paint thinner aerosol cans on nearby countertops or in adjacent cabinetry Follow the directions in this manual exactly Use the hood only as intended by the manufacturer If you have questions contact Dacor Pg 3 Installation and wiring must be done by qua...

Page 5: ...rols Never let the filters become blocked clogged or foreign objects e g cigarettes napkins be sucked into the hood Do not use window coverings that could blow over the cooking surface and hood Use only metal ducting The minimum vertical distance between the cooking surface and the lowest part of the hood must be 30 76 2 cm See the instructions in this manual for this distance in your specific cas...

Page 6: ... assembled as instructed Pg 30 The setup was verified Any problems were noted on the warranty card or during the online warranty activation The warranty card was completed and mailed or the warranty was activated online Preparing to Install the Hood Have these tools and hardware available before starting the installation Phillips screwdriver Flat head screwdriver Pencil marking tool Wire connector...

Page 7: ...the Hood cont Parts List Installation Planning The owner shall ensure that the hood is installed by qualified personnel The hood should be placed for convenient access Ensure that electrical power can be provided to the selected location and that the outlet is easily accessible for service emergency shutoff All minimum clearances must be met Dimensions shown provide minimum clearances unless other...

Page 8: ...120V 60 Hz 15 Amp actual load 6 1 Amp 12 Amp initial surge Lights Dimmable LED PAR16 E26 27 120V 7 5W 75W Max other bulbs Components 48 36 30 Lights 4 3 2 Filters Blowers 2 1 1 Exhaust Vents Blower Rating 1200 CFM 600 CFM 600 CFM General Individual Models DHD30 36 48 Model Weight 30 53 lbs 24 kg 36 57 lbs 26 kg 48 77 lbs 35 kg Weight Individual Models DHD30 36 48 Model Top Vent Rear Vent Rotatable...

Page 9: ...a Electrical access holes 2 Model A B C 48 1 1 2 3 81 cm 5 12 7 cm 36 4 1 2 11 43 cm 30 5 1 2 14 cm Dual Exhaust Standard 8 duct Single Exhaust Standard 8 duct See table 5 3 4 in 14 6 cm 1 1 2 3 81 cm 1 1 2 3 81 cm 3 7 62 cm Rear Connections All models Dual Exhaust Standard 8 duct Hood bottom 19 3 4 in 50 2 cm Hood C L 9 7 8 in 25 1 cm See table 5 3 4 in 14 6 cm Single Exhaust Standard 8 duct Dual...

Page 10: ...irements Overall Hood Dimensions Tolerances 1 16 0 unless otherwise stated Single Blower DHD30 36 Series Model A B C D 30 29 7 8 75 9 cm 24 61 cm 18 45 7 cm 12 30 5 cm 36 35 7 8 91 1 cm 48 47 7 8 121 6 cm Dual Blower DHD48 Series ...

Page 11: ...yout Dimensions Tolerances 1 16 0 unless otherwise stated Electrical access top and back of hood hood bottom to cooking surface 30 min 76 2 cm Min Width of E Upper Cabinet Cutout Appliance Width Model DHD E 30 30 76 2 cm 36 36 91 5 cm 48 48 121 9 cm ...

Page 12: ...ic permanent wiring system or to a grounding conductor installed by a licensed electrician Do not ground the unit or its wiring to a gas pipeline or to the neutral white power supply wire Do not install a fuse in the neutral or ground circuit Connect the hood directly to an electrical junction box Hard wire the hood per local code directly to a dedicated 3 wire grounded single phase circuit rated ...

Page 13: ...cooktop All dimensions must fall within specified minimums Dimensions given are minimum clearances unless otherwise noted All contact points between the hood and cabinetry walls must be sturdy solid and at right angles Install the hood so it can be removed for service WARNING Follow local codes during planning installation Contact the local building department for details Use only code approved du...

Page 14: ...ay require makeup air systems to be used with ventilation systems that move air at greater than the specified rate CFM which rate depends on locale In designing the system consult an HVAC specialist for local requirements and to ensure best performance All ductwork material incl screws and foil tape shall be provided by the customer Ductwork must not interfere with floor joists or wall studs On du...

Page 15: ...ely cold weather regions use thermal breaks i e short sections of non metallic duct to avoid indoor heat loss Put the break as close to the outside pass through point as possible Do not use flexible metal ducting or ductwork smaller than what the tables advise The hood exhaust connects to an 8 round duct You can increase the duct size over the duct run To prevent backdraft never decrease the duct ...

Page 16: ...on hood back If mounting the hood to brick or masonry Select anchors rated for the hood s weight Properly reinforce the mounting surface to support the hood s full weight DHD Models Weight 30 53 lbs 24 kg 36 57 lbs 26 kg 48 77 lbs 35 kg Mounting Block Studs If mounting the unit to drywall or a plastered surface install a reinforced mounting block between the studs Attach screws directly to the stu...

Page 17: ...he distance from the edge of the hood to the center of the exhaust port Transfer that measurement to the wall for a rear vent or overhead for top vent Measure the X and Y axes to find the centerline Extend the line down 10 inches 25 4 cm Cut a hole 1 inch larger than the duct Dual exhaust models require two holes Measurement Location Measurement in cm A 9 7 8 in 25 08 cm B 14 1 8 in 35 88 cm C 48 ...

Page 18: ...horizontal centerline 2 1 8 5 4 cm below the top of the hood Image 1 NOTE Minimum distance bottom of cabinets to cooktop 30 76 2 cm 2 Measure and mark the centerline Image 1 halfway between the cabinets If there are no cabinets above the cooktop measure and mark the cooktop centerline 3 Referring to Image 1 and the above table measure the A distance left and right from the centerline between the c...

Page 19: ...intend to use that configuration you do not need to alter the blower s position If however the hood will be installed for rear exhaust the blowers can be rotated so exhaust vents out the back Fig 2 NOTE The hood images in this section were chosen to illustrate procedures and may not depict the hood being installed Tools Needed 5 16 nut driver Cable ties AHT10 Transition kit option metal screws foi...

Page 20: ... and wires always pull by the connector 6 Unscrew the cable clamp s and remove the hardware that holds the blower and L bracket 7 Detach the blower and plate and set them aside Configuring the Vent L Brackets Default Blower Configuration Top vent open no rear vent Blower Vent L Bracket Back of Hood Rotated Blower Configuration Open rear vent No top vent Back of Hood Blower Vent L Bracket 1 Unscrew...

Page 21: ...ers exit vent 1 2 Set the hood on its top Standing at the rear of the hood and looking down at the blower insert the blower so its I O port faces right and its exhaust port is against the L bracket at the rear of the hood Finalizing the Rear Vent Setup Duct collar Right Rear Top 1 Refasten the cable clamps and assembly to the hood 2 Connect the cable assembly to the blower s I O port 3 Attach the ...

Page 22: ...ood Replacement Part Description 702579 Baffle Filter Kit 1 pc hardware 702580 Baffle Filter Kit 2 pc hardware Using the Optional Dual to Single Transition Kit AHT10 2 5 1 cm 3 4 1 9 cm 9 22 9 cm 32 81 3 cm 13 3 4 34 9 cm On dual exhaust models the two 8 duct exhausts can be transitioned into one 10 duct Assemble the Dacor transition kit AHT10 sold separately before you hang the hood This transiti...

Page 23: ...T10 unit s base Hanging the Hood WARNING Hanging the range hood requires two people Do not lift the hood unassisted IMPORTANT Take care not to scratch damage the hood Hanging slots in the hood back engage the holding brackets to support the hood temporarily during installation 1 Remove the plastic film from the hood 2 Lift and slip the hood onto the holding brackets through the hanging slots in th...

Page 24: ... the hood through an electrical junction box or a dedicated 15 Amp circuit breaker WARNING Before connecting the wiring turn OFF power to the hood at the fuse box or circuit breaker Miswiring the hood creates an electric shock or fire hazard and may harm its electrical system Do not ground the wires to the neutral white wire Connect the ground wire to a separate properly grounded wire installed by...

Page 25: ... Remove the wing nut on the main power switch plate then remove the plate to access the terminal block and connect the power wires 5 Insert the white wire and black wire through the plastic hole protector and tighten the wires to their corresponding terminals Junction box Wire nut 3 places UL CSA approved NEMA strain relief To range hood To house circuit breaker or fusebox WHITE WHITE BLACK BLACK ...

Page 26: ...nnel or other surfaces Insert the filters a Set the front edge against the clip and press b Lift the rear edge above the grease channel c Set the filter rear edge on the grease channel 5 On the control panel press Lights to verify that all lights turn on 6 Press Lights to turn the lights to Low then press again to turn the lights off 7 Press POWER to verify that one fan speed indicator turns on an...

Page 27: ...English 27 Installation Instructions Wiring Diagram DHD30 36 48 ...

Page 28: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Reviews: