Meeting Electrical Codes
•
The owner shall verify that all electrical requirements are met by the
installer
.
•
The electrical installation (incl. minimum supply-wire size and grounding) must comply with the
National Electric code ANSI/NFPA (or latest revision), and local codes. Obtain a copy of the
ANSI/NFPA standard from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
•
The
hood's
ground terminal must be connected to a grounded, metallic, permanent wiring
system, or
to
a grounding conductor installed by a licensed electrician.
•
Do not ground the
unit
or
its
wiring to a gas pipeline or to the neutral
(white) power supply wire.
•
Do not install a fuse in the neutral or ground circuit.
•
Connect the hood directly to an electrical junction box. Hard-wire the hood per local code
directly to a dedicated,
3
-wire
,
grounded, single-phase circuit rated at 120 Vac 60 Hz, 15
Amp.
WARNING
Electrical Shock Hazard
Ensure a licensed electrician installs the electrical service to the range hood.
Preparation and Setup
This diagram shows the top and rear locations for wire access into the hood.
Top Access
Rear Access
See Wiring Diagrams at the end of this document.