20
English
I
nstallation
Instruction
s
Rotating the Blowers for Rear Exhaust, cont.
Removing Components
, cont.
L-Bracket
Plate
Blower
4. Carefully set the hood on its back to access the
bottom.
5. Find the end of the cable assembly plugged into
the bottom left of the blower, then squeeze and
unplug the connector. (To avoid damaging the
cable-assembly contacts and wires, always pull by
the connector.)
6. Unscrew the cable clamp(s), and remove the
hardware that holds the blower and L-bracket.
7. Detach the blower and plate, and set them aside.
Configuring the Vent L-Brackets
Default Blower
Configuration:
Top vent open;
no rear vent
Blower/Vent
L-Bracket
Back of Hood
Rotated Blower
Configuration:
Open rear vent-
No top vent
Back of Hood
Blower/Vent
L-Bracket
1.
Unscrew, and remove the L-bracket that is in the default top-venting configuration
(left)
.
2.
Turn and align the L-bracket so the hole is in back of the hood
(right)
.