Figure 3-32 Schematic Diagrams for the Connection of the AC Power Cable
Precautions
Before connecting the power supply, you must verify that the external power supply matches the power module
installed in this equipment.
Before connecting the power cable, be sure that the switch of the power module is in the OFF position.
The power cable with a standard 3-pin connector should be used for connection.
Be sure that the power cables connected are in good contact.
Simple Connection Steps
1)
Insert the plug of the power cable into the power module.
2)
Connect the other end of the power cable to the corresponding socket or connector.
When installing the unit, use 3-pin power supply cord. The cross-sectional area of each pin is 1.5 mm
2
or 14AWG
minimum.
Connecting the Cables of the Management Module
Simple Connection Steps
1)
Connect the end of the Ethernet cable with the RJ-45 connector to the Ethernet port of the equipment management
module (M8614/M8610/M8606-CM II), and the other end to the NMS or control terminal.
2)
Connect the DB-9 female to the serial port of the PC or terminal on which the switch is configured, and the RJ-45 end
to the console port of management board.
The RG-S8614/S8610/S8606/S8606 B system must have at least one management module to work normally.
Summary of Contents for RG-S8614
Page 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Page 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Page 62: ...Figure 2 6 Ventilation of RG S8614 ...
Page 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Page 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Page 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Page 116: ......