Status
System LED
OFF: The module is not powered on.
Red: The module is faulty.
Blinking green: The module is initializing. If it keeps blinking, the
module may be faulty.
Solid green: The module has finished initialization and can
perform switching well.
Specifications
Model
M8600-NMM
Standard Compliance
IEEE 802.3-2005 Ethernet Standard
LED
Status
Hot Swapping
Supported
Power Consumption
<140W
EMC Standards
GB9254-2008
Safety Standards
GB4943-2011
Operating
Temperature
0 to 40°C
Storage Temperature
-40 to 70°C
Operating Humidity
10% to 90% RH (non-condensing)
Weight
Net weight: 3.0 kg
Dimensions
(L x W x H)
436 mm x 346 mm x 45 mm
M8600-08XFP
Module Appearance
Figure 1-28 Appearance of the M8600-08XFP
External Interface
The M8600-08XFP provides eight 10G XFP ports. The XFP optical modules support hot swapping.
LED
Sign
Description
Detailed information
Status
System LED
OFF: The module is not powered on.
Red: The module is faulty.
Blinking green: The module is initializing. If it keeps blinking, the
module may be faulty.
Solid green: The module has finished initialization and can perform
switching well.
Link/ACT
Port status LED
OFF: The port link is not up.
Green: The port link is up.
Blinking green: The port is sending and receiving data.
Specifications
Model
M8600-08XFP
Standard Compliance
IEEE 802.3-2005 Ethernet Standard
Port Type
Eight 10G XFP ports.
Transmission Medium
10GBASE-SR(850nm)
Multi-mode optical fiber
10GBASE-LR(1310nm)
Single-mode optical fiber
10GBASE-ER(1550nm)
Single-mode optical fiber
LED
Status, Link/ACT
Hot Swapping
Supported
Power Consumption
<250W
EMC Standards
GB9254-2008
Safety Standards
GB4943-2011
Operating
Temperature
0 to 40°C
Storage Temperature
-40 to 70°C
Operating Humidity
10% to 90% RH (non-condensing)
Summary of Contents for RG-S8614
Page 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Page 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Page 62: ...Figure 2 6 Ventilation of RG S8614 ...
Page 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Page 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Page 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Page 116: ......