Backplane
The RG-S8614 switch
’s backplane interconnects high-speed data links from switch management board to module circuit
board and various management and control signals between modules. Its functions are as follows:
Interconnects all signals between modules and provide high-speed communication channel.
Passive backplane
Supports active/standby switching between management modules
Supports automatic identification of various slots
Implements distributed power supply
Introduces monitoring signal lines of the fan and power supply
Ventilation and Heat Dissipation System
The operating temperature of the RG-S8614 switch is 0 to 40°C. The thermal design must ensure that the surface
temperature of the components does not exceed 50% to 80% of the allowed maximum temperature and satisfy the
requirement on the device’s reliability in the temperature range while ensuring the device’s reliability, safety and
maintainability. According to the thermal design of the RG-S8614 switch, fans are used to draw air for forced convection
cooling in order to ensure that the device works properly in the specified environment.
Summary of Contents for RG-S8614