DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
930
96-30
config wireless wids_security wired_detection_interval
Description
This command is used to specify the minimum wired detection interval. Use this variable to set the
minimum number of seconds that the AP waits before starting a new wired network detection cycle.
Format
config wireless wids_security wired_detection_interval [<int 0-3600> | default]
Parameters
<int 0-3600>
- Enter the minimum wired detection interval here. This value must be between 0
and 3600 seconds. The default option is 60 seconds. This value 0 means that detection will be
disabled.
default
- Specifies that the default value will be used.
Restrictions
Only Administrators can issue this command.
Example
To disable the wired detection interval:
DWS-3160-24PC:admin#config wireless wids_security wired_detection_interval 0
Command: config wireless wids_security wired_detection_interval 0
Success.
DWS-3160-24PC:admin#
96-31
show wireless wids_security
Description
This command is used to display the WIDS security settings and status.
Format
show wireless wids_security
Parameters
None.
Restrictions
None.
Example
To display the WIDS security settings and status: