DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
652
Parameters
time_interval
– Specifies the interval used to save the log to the flash. (If no new log events
occur in this period, don't save.)
<min 1-65535>
- Enter the time interval value here. This value must be between 1 and 65535
minutes.
on_demand
- Save log to flash whenever the user enters the "save log" or "save all" command.
The default setting is on_demand.
log_trigger
- Save log to flash whenever a new log event arrives.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure the method for saving a log as on demand:
DWS-3160-24PC:admin# config log_save_timing on_demand
Command: config log_save_timing on_demand
Success.
DWS-3160-24PC:admin#
69-12
show log_save_timing
Description
This command is used to display the method for saving the log.
Format
show log_save_timing
Parameters
None.
Restrictions
None.
Example
To display the timing method used for saving the log: