High Water Mark and High Water Time:
These parameters specify the conditions under which the second channel
will be activated. When the utilization of the first connected channel goes
over the High Water Mark and passes the High Water Time, the additional
channel will be activated. The link speed will then be 128kbps .
The default value for High water mark is 56 kbps and the default value for
High water
These parameters are enabled only when connection type is BOD (Bandwidth
On Demand). Default values highwater mark and highwater time are 7000 bytes
and 30
seconds respectively
.
Automatic applying of ISDN pages:
Whenever user clicks on apply in the ISDN Connection page, then
depending upon the connection type automatically dialout and dialin pages
will be applied.
Automatic apply of dialout pages:
Dialout page will be applied with
appropriate profile if he/she has configured it previously. User has to
configure profile for each connection type (i.e. 64K B1, 64K B2 and
128K) at least once.
-If user has selected connection type as 128K dialin/dialout or BOD
dialout and he has configured a profile for this connection type then that
profile will automatically be applied.
-If user has selected connection type as 6464kdialout and he has
configured a profile for channel B1 that profile will be applied
automatically.
- If user has selected connection type as 2 64kdialout and he has
configured profiles for both channel1 (B1) and channel2 (B2) then those
profiles will automatically be applied.
Automatic apply of dialin pages:
Dialin page is automatically applied
with appropriate profile if they are configured previously.
-If user configured profile for B1 previously then when user selects
connection type 128K dialin/dialout or 2 64Kdialin then B1’s profile will