CY3210-PSoCEVAL1 PSoC® 1 Evaluation Kit Guide, Doc. #: 001-66768 Rev. *F
35
Code Examples
Figure 5-6. Multi User Module
The user module (UM) is placed in the first available analog block. By default, the UM is placed
on an Analog Switched Capacitor Type C block. It should be shifted to a Switched Capacitor Type
D block, as explained in the next step.
Note
The analog block in ADCINC is configured as an integrator. Switched Capacitor Type C is
a filter and Type D is an integrator. Refer to the ADCINC UM data sheet and Technical Reference
Manual from
Help
>
Documentation
for more details on analog blocks.
11. To change the UM placement, click on
Next Allowed Placement
). The next
possible module for placement is highlighted. Click on the icon again so that the ASD11 analog
block is highlighted. Now, click on the
Place User Module
icon (see
) to place the user
module in ASD11 analog block.
Figure 5-7. PSoC Designer Toolbar
Place User Module
Next Allowed Placement