Document Number: 002-04578 Rev. *A
Page 43 of 64
MB90910 Series
11.4 AC Characteristics
11.4.1 Clock Timing
Parameter
Symbol
Pin name
Value
Unit
Remarks
Min
Typ
Max
Clock frequency
f
C
X0, X1
3
16
MHz
1/2 when PLL stops,
When using an oscillation circuit
4
16
MHz
PLL
1,
When using an oscillation circuit
4
16
MHz
PLL
2,
When using an oscillation circuit
4
10
MHz
PLL
3,
When using an oscillation circuit
4
8
MHz
PLL
4,
When using an oscillation circuit
4
5
MHz
PLL
6,
When using an oscillation circuit
4
4
MHz
PLL
8,
When using an oscillation circuit
Clock cycle time
t
CYL
X0, X1
62.5
333
ns
When using an oscillation circuit
Internal operating clock fre-
quency
(machine clock)
f
CP
1.5
32
MHz
When using main clock
Internal operating clock cy-
cle time
(machine clock)
t
CP
31.25
666
ns
When using main clock
t
CYL
X0, X1
When using an oscillation circuit
Amplitude:
It varies depending on the
external resistance, power
rating and the different kind of
device.
Reference values: 1V to 2.5V
Note : The amplitude of MB90V950AMAS is the same as Vcc.