background image

7. Time Setting

Step 1:   
power on, in the standby status, press and hold 

(mandatory flushing button), then press 

(power 

button), 2 seconds later 

(time code) lights up. 

Step 2:   
release 

(power button) and 

(mandatory flushing button), 

(time code) flashing, press 

(power 

button) can modify the flashing digital. 
Step 3:   
after setting finished, press 

(mandatory flushing button) can switch the flashing digital. 

Time modification: 
The  time  of  water  producing,  water  storing, 
back  washing,  forward  washing  can  be 
modified.   

Time  modification  is  divided  into  five  stages: 
water  producing  1,  water  producing  2, 
flushing 1, flushing 2, flushing 3.   

The  corresponding  time:  water  producing 
time  (0~99hour),  water  producing  time 
(0~59min),  water  storing  time  (0~99sec), 
back  washing  time  (0~99sec),  forward 
washing time (0~99sec).   

The corresponding status shown on the panel: 
“filtration  indication  +  number  1”  lights  up, 
“filtration  indication  +  number  2”  lights  up, 
“flushing  indication  +  number  1”  lights  up, 
“flushing  indication  +  number  2”  lights  up, 
“flushing indi number 3” lights up.     

Summary of Contents for 82C

Page 1: ...h Flow Ultra Filtration System 82C For Support Call 1 831 462 8500 Email support cleanwaterstore com Clean Water Systems Stores Inc 2806 A Soquel Ave Santa Cruz CA 95062 Visit Us Online www cleanwaterstore com ...

Page 2: ...rals and trace elements Wall mounted design saves space and easy for installation Microcomputer automatically backwash program prolongs the lifespan of UF membrane reduces the operation cost LCD display direct viewing and convenient Automatic backwashing and rinsing of UF system 4 Product Specifications 4 1 Components Controller Microcomputer UF filter Backwash Pressure tank 4 2 Specifications Ite...

Page 3: ...emperature 5 45 Connector size G3 4 Dimensions 423 247 1060 mm Weight 37 kg Installation requirements Floor drain AC 220V 50Hz Energy consumption 15W 5 Product Structure A Pressure tank connector B Purified water outlet C Raw water inlet D Discharge outlet E Installation hole ...

Page 4: ...s button to turn ON OFF the device operation when the device is in the stop condition all valves are closed adopted electric valves 4 Time code shows the time of each stage water producing water storing back washing forward washing If the time code is not flashing press power button to enter into the next stage time setting After time setting in any stage press mandatory flushing button for 2 seco...

Page 5: ...me of water producing water storing back washing forward washing can be modified Time modification is divided into five stages water producing 1 water producing 2 flushing 1 flushing 2 flushing 3 The corresponding time water producing time 0 99hour water producing time 0 59min water storing time 0 99sec back washing time 0 99sec forward washing time 0 99sec The corresponding status shown on the pa...

Page 6: ...9 Working Process 1 Filtration Under the action of water pressure raw water through DD1 and enters into UF filters DD2 is closed at the moment DD3 opens filtered water comes out 2 Flushing a DD1 opens DD2 DD3 are closed pressure tank starts to store water 20 seconds b After water storing finished DD1 DD3 are closed DD2 opens water stored in the pressure tank starts to back wash UF filters the flus...

Page 7: ...e tank storing water 20 seconds ON OFF OFF Back wash 20 seconds OFF ON OFF Forward wash 20 seconds ON ON OFF Remarks Above time settings can be changed but the operation sequence cannot be changed Above timings are factory setting can be reset according to user s requirements Typical Apartment Residential Application ...

Reviews: