background image

PORTABLE 

COLOR

DISPLAY

(TFT) 

WORLDWIDE 

REMOTE 

CONTROL

WIFI and 
MODBUS

SEA  

WATER

SELF  

CLEAN

UPGRADE 

POSSIBLE

from

SALT/L

1,5g

INSTALLATION GUIDE

1

Oxilife is a water treatment system and a controller for 
swimming pools.This water treatment combines electrolysis of 
low salinity with hydrolysis.
With the electrolysis of low salinity we produce liquid chlorine 
from water which is very slightly salted (from 1,5 to 2,5 g salt 
per liter). The hydrolysis produces disinfectants such as oxygen, 
peroxide, hydroxyls and ozone. All these oxidants combat and 
eliminate organic matter and pathogenic agents present in the 
water. The used chlorine reconverts into salt, and the oxidants of 
the hydrolysis reconvert into water on its way back to the pool.
Oxilife controls centrally all the components of your pool, 
ensuring an efficient interaction.

DESCRIPTION

Electronic box

Low salinity 

electrolysis
RCA flow detector
Main connection 230 V
ON/OFF switch

1

2
3
4

1

2

3

4

5

6

Fuse for device and cell 3.15 A
Fuse relays 3.15 A


6

110-230 V

*

 An “Installer Menu” does exist for advanced functions. If you are an authorized installer, please ask your provider for the installers/service manual.

Connection  

WIFI / RS module

Device control SLAVE
Digital inputs / outputs

Connection display

Electrical connections of the electronic box

Chlorine probe 

detector 

(rotameter)

Cover

FL1

Conductivity probe

Temperature probe

pH

redoX

Free 

Chlorine

Low salinity electrolysis cell

RCA flow detector

Cell connector

Cell housing

Flow/gas detector 

(internal)

1

2

3

4

5

Cell

Optional automatic controls

Conductivity

Metering and control of 

the conductivity of the 

water in Msiemens.

Flow detector

Temperature

Mechanic security flow 
switch. Stops the low 
salinity electrolysis if 
there is no water flow.

Temperature  probe 

0 - 100° C necessary 

to activate the filtration 

modes: heating / 

intelligent / smart.

redoX control

Free chlorine control

pH control

Metering and control 

of the pH of the water.

Metering and control of 

the redoX as check value 

of the free chlorine. 

Metering and control in 

ppm of the free chlorine 

of the water.

DRY CONTACT

110-230 V 

max. 3.15 A

NEW 

MODEL  

2015

FAN

LESS

!

1

2

3

4

5

pH

pH Control

AUX 1

Base (pump)*

AUX 2

redoX / free chlorine 

ppm´s (pump)*

AUX 4

Heating control*

AUX 3

LIGHT

Lighting control

FILTER PUMP

Filtration control

14

12

11

A1 A2

L

N

Summary of Contents for oxilife

Page 1: ...for advanced functions If you are an authorized installer please ask your provider for the installers service manual Connection WIFI RS module Device control SLAVE Digital inputs outputs Connection display Electrical connections of the electronic box Chlorine probe detector rotameter Cover FL1 Conductivity probe Temperature probe pH redoX Free Chlorine Low salinity electrolysis cell RCA flow detec...

Page 2: ...lt concentrations from 2 5 g l to 50 g l s In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid Water adjustments Adding salt to the water 4 5 6 3 INITIAL WATER ADJUSTMENTS hydrolysis measures pH 7 5 OFF OFF 7 0 7 2 Rx mV 700 OFF FL1 700 man off man off 12 30 25º 100 1 2 3 4 Cover Pol 1 Low 4 FUNCTIONING OF THE SYSTEM Current time Hydrolysis Intensity of th...

Page 3: ... actual temperature use the plus minus and up down keys Set to the actual temperature of the probe and press OK 2 9 Calibration of the redoX probe Recommended every 2 months during usage season 2 10 Calibration with buffer buffer liquid 465 mV Follow the instructions which appear on the displays fig 2 11 You can access the display Filter cleaning from any filtration mode Once selected this functio...

Page 4: ...ting of preferred language 6 5 Setting of day and current time 6 7 Setting of the intensity of the display lighting 0 100 and programming its ON and OFF time 4 6 Settings 6 12 6 14 6 13 6 1 6 3 6 4 6 2 6 5 6 8 6 9 6 6 6 11 6 7 6 10 2 x Clima OFF The heating only works within the set filtration periods Clima ON Keeps the filtration working when the filtration period is finished if the water tempera...

Page 5: ...ol water is not recommendable We recommend that the system runs 2 3 times per week 2 3 hours per day DOSING PUMPS Check regularly to ensure that the container contains liquid to prevent the dosing pump of running dry The dosing pump requires maintenance SEE INSTRUCTIONS ON BOX pH PROBES redoX CONDUCTIVITY Probes must be cleaned whenever necessary check every 5 6 months To clean the probe insert in...

Page 6: ...section 3 Initial water adjustments s Check for incrustations on cell s See section 7 Electrolysis does not reach maximum intensity Electrolysis display shows LOW s The water is excessively hard and it is unbalanced s Balance the water and check the cell proceeding to clean it if necessary s Put 1 small bag of flocculant in the skimmer and recirculate 24 hours White flakes in the water s Check flo...

Reviews: