background image

6. Controller Panel

filtration indication

flushing indication

power button

flushing stage indication

time code

mandatory flushing button

(1) Filtration indication

:

during the filtration process, the water drop-shaped drips from top to bottom, the ripple spreads
out from inside to outside.

(2) Flushing indication

:

after 40 minutes filtration, it enters into flushing process. The icon shows that:
flushing 1: pressure tank storing water;
flushing 2: pressure tank backwashing;
flushing 3: forward washing.

(3) Power button

:

press this button to turn ON/OFF the device operation, when the device is in the stop condition,
all valves are closed (adopted electric valves).

(4) Time code

:

shows the time of each stage (water producing, water storing, back washing, forward washing). If
the time code is not flashing, press 

(power button) to enter into the next stage time setting.

After time setting in any stage, press 

(mandatory flushing button) for 2 seconds can save the

set time, the new set time will take effect on the next startup.

(5) Mandatory flushing button

:

when press this button, the device will execute once flushing process.

(6) Electricity lost detection function:

for water safety guarantee, if there is no city electricity, all valves will be closed automatically.

Summary of Contents for 82C

Page 1: ...h Flow Ultra Filtration System 82C For Support Call 1 831 462 8500 Email support cleanwaterstore com Clean Water Systems Stores Inc 2806 A Soquel Ave Santa Cruz CA 95062 Visit Us Online www cleanwaterstore com ...

Page 2: ...rals and trace elements Wall mounted design saves space and easy for installation Microcomputer automatically backwash program prolongs the lifespan of UF membrane reduces the operation cost LCD display direct viewing and convenient Automatic backwashing and rinsing of UF system 4 Product Specifications 4 1 Components Controller Microcomputer UF filter Backwash Pressure tank 4 2 Specifications Ite...

Page 3: ...emperature 5 45 Connector size G3 4 Dimensions 423 247 1060 mm Weight 37 kg Installation requirements Floor drain AC 220V 50Hz Energy consumption 15W 5 Product Structure A Pressure tank connector B Purified water outlet C Raw water inlet D Discharge outlet E Installation hole ...

Page 4: ...s button to turn ON OFF the device operation when the device is in the stop condition all valves are closed adopted electric valves 4 Time code shows the time of each stage water producing water storing back washing forward washing If the time code is not flashing press power button to enter into the next stage time setting After time setting in any stage press mandatory flushing button for 2 seco...

Page 5: ...me of water producing water storing back washing forward washing can be modified Time modification is divided into five stages water producing 1 water producing 2 flushing 1 flushing 2 flushing 3 The corresponding time water producing time 0 99hour water producing time 0 59min water storing time 0 99sec back washing time 0 99sec forward washing time 0 99sec The corresponding status shown on the pa...

Page 6: ...9 Working Process 1 Filtration Under the action of water pressure raw water through DD1 and enters into UF filters DD2 is closed at the moment DD3 opens filtered water comes out 2 Flushing a DD1 opens DD2 DD3 are closed pressure tank starts to store water 20 seconds b After water storing finished DD1 DD3 are closed DD2 opens water stored in the pressure tank starts to back wash UF filters the flus...

Page 7: ...e tank storing water 20 seconds ON OFF OFF Back wash 20 seconds OFF ON OFF Forward wash 20 seconds ON ON OFF Remarks Above time settings can be changed but the operation sequence cannot be changed Above timings are factory setting can be reset according to user s requirements Typical Apartment Residential Application ...

Reviews: