4. Appliance Installation Procedure (For User Reference Only)

 

 

Clearances between the appliance and all combustible materials must conform to 
national regulations. 
 

The appliance must be installed and used in accordance with these instructions. Prior 
to installation, ensure that the local distribution conditions (identification of the type 

of gas and pressure and the adjustment of the appliance) are compatible. 
 

The builders opening or fireplace opening must be constructed of a non-combustible 
material. 

 
Any flue damper plate or flue restrictor must be removed or fixed permanently in a 

fully open position, or shall only be installed in accordance with national regulations. 
 

The chimney must be swept before the appliance is installed. If the chimney is not 
swept, there is a possibility that loose debris will fall onto the burner unit which will 

result in damage and unnecessary service costs. 
 

Before the appliance is installed a flue test in accordance with national regulations 
should be carried out. The appliance must not be installed unless the chimney or flue 

length is at least the length and size indicated in the section marked ‘Appliance 
Technical Data’ in the Installation Manual. 

 
Under no circumstances should the appliance be installed and operated within any 

premises without an adequate flue or chimney system. 
 
An air supply must be installed in accordance with national regulations and should be 

checked regularly to ensure that it is free from obstruction. 
 

Soundness of the input gas line should be checked prior to installing the appliance. 

 

The gas connection must be made in accordance with national regulations. 
 

An isolation valve (stop tap) must to be installed adjacent to the appliance, which, 
when closed allows the complete burner and control assemblies to be disconnected for 

maintenance and repair in accordance with national regulations. 

Summary of Contents for Fire Wave

Page 1: ...ual must be handed to the owner of the property once the appliance is commissioned and retained onsite for operation and servicing reference The appliance has a manufacturer s warranty valid for 1 yea...

Page 2: ...Appliance Spare Parts 13 Appliance Warranty 14 Fitting The Optional Wall Switch 15 Converting The Fire To Mains Supply 16 Contact Details 17 User Manual Every appliance has been designed manufactured...

Page 3: ...ressure AT BE CH CY CZ DE DK EE ES FI FR GB GR HR HU IE IT I2H G20 at 20mbar 9 9 9 9 9 9 9 9 9 9 9 9 I2E G20 at 20mbar 9 NG I2E G20 G25at20 25mbar 9 9 I3P G31 at 37mbar 9 9 9 9 9 9 9 9 9 I3 G30 G31 at...

Page 4: ...gineer Warning Do not adjust the system Warning Do not disable the flame sensing device Warning Use only OEM parts The installation should only be carried out by a GAS SAFE Engineer and in accordance...

Page 5: ...to ensure a long life Note that if the fire shuts down it is automatically set in safe mode to reactivate the fire press button 1 only on the handset This will cause a beep Now the fire can be lit ag...

Page 6: ...ey is not swept there is a possibility that loose debris may fall onto the burner unit which may result in damage and unnecessary service costs Before the appliance is installed a flue test in accorda...

Page 7: ...to observe this will result in serious heat damage to the remote system This will not be covered by the warranty The normal way to do this is by creating a ducted space behind the plasterboard from t...

Page 8: ...gather unit attached This is required in order to ensure the fire operates safely and inline with the CE approval The enclosure is then inserted into the opening and positioned so that the front edge...

Page 9: ...un with a gas supply which is not suitable it will render the appliance unreliable and possibly dangerous Once the fire is connected the gas must be tested at the test point within the fireplace enclo...

Page 10: ...t in incorrect flame activity and damage to the remote system Any resulting damage caused by incorrect installation is not covered by the warranty GAS LEAKS With the isolation valve in the appliance s...

Page 11: ...is operated via a hand set and magic eye positioned on the right hand side of the enclosure There is also a manual wall switch Step 4 Light the appliance as shown in section 7 Once lit turn the appli...

Page 12: ...ppliance must be serviced every 12 months and that chimney or flue system should be checked regularly to ensure the appliance operates at optimum performance Step 10 The warranty card is to be complet...

Page 13: ...s There are two methods of lighting the appliance Hand Set Infra Red and Manual Wall Switch this is an optional extra to order call 01325 327221 8 1 Using the Remote Control Handset see image The hand...

Page 14: ...tion sequence press Button 1 again STANDBY MODE o It is possible once the fire is lit to operate in standby mode with pilot only lit To do this press button 2 HIGH LOW FLAME o By pressing Button 3 inc...

Page 15: ...ton 1 again It is possible once the fire is lit to operate in standby mode with pilot only lit To do this press button 2 By pressing Button 3 the burner flame is increased to the maximum rate By press...

Page 16: ...lf taking care that the appliance will be hot The reset button is fitted to the top of the remote shield Carefully insert hand below the shelf taking care not to touch any hot surfaces Press and hold...

Page 17: ...he pilot Appliance sparks but does not light pilot Check that there is gas at the input and at the pilot Check that remote valve is operating correctly Check isolation tap shut off is open If there is...

Page 18: ...nual wall switch Appliance does not respond to commands from the remote control handset Check that the IR receiver is correctly positioned with dome face outwards If the light on the remote control do...

Page 19: ...2 minutes before adding the new batteries If the sound is still present after adding new batteries execute an ignition sequence 3 x beeps Manual Wall Switch Keyboard Failure Substitute the keyboard wi...

Page 20: ...y Remote System Schematic Schematic of Battery Remote System All parts are required to ensure system operates safely and efficiently To order replacement parts please call 01325 327221 and ask for cus...

Page 21: ...moved the surfaces can be cleaned with the use of a soft cloth and a hand held stainless seel cleaner which is available from most supermarkets Removing spillages This appliance has an electronic remo...

Page 22: ...art Codes There are no user serviceable parts on the appliance Spare parts which are available to order for replacement by a registered Engineer are 1 Battery Remote Parts NiCad Batteries Charger Magi...

Page 23: ...ontrol Valve the high setting is pre set however the low setting must be done once the valve has been changed This can be done by using the screw on the valve and the plug capped with suitable sealer...

Page 24: ...ocket and the manual switch panel must be disconnected from the black box 6 The burner tray will now be able to be slid forward and lifted out of the enclosure 7 Refit the shelf REFITTING THE BURNER U...

Page 25: ...is for 12 months and covers defective manufacture and components only The warranty does not cover damage due to incorrect installation or site specific problems Chimney Flue Gas Pressure etc The appli...

Page 26: ...Page 26 of 42 14 Fitting the Optional Wall Switch Important This work must be carried out by a GAS SAFE REGISTERED ENGINEER...

Page 27: ...Page 27 of 42 Remote Diagram Take some time to review the attached diagram NOTE THE POSITION OF THE LINK...

Page 28: ...all switch in the required place and connect the cable Refit the heat shield on the remote system Reconnect gas and check for leaks Review the section on lighting the fire to ensure the wall switch op...

Page 29: ...ese are available as optional spare parts from the customer service department Call 01325 327221 2 Procedure a Remove the remote heat shield and disconnect the battery pack supply lead and reset switc...

Page 30: ...on 17 Aug 2009 There may be changes made in future as we improve our products If there are any queries please write to or call our technical department The CVO Fire brand is owned and manufactured by...

Page 31: ...nufacturer s warranty valid for 1 year from date of delivery In order to validate the warranty the appliance must be installed by a GAS SAFE Engineer The warranty card supplied with this booklet shoul...

Page 32: ...Appliance Warranty 12 LPG Bottles 13 Contact Details Every appliance has been designed manufactured and type tested to ensure that it conforms to the current national and European DFE decorative fuel...

Page 33: ...ermocouple electrode and injector the complete assembly must be replaced with an original manufacturer s pilot assembly by a GAS SAFE Engineer Warning Do not adjust the system Warning Do not disable t...

Page 34: ...burner unit which will result in damage and unnecessary service costs Before the appliance is installed a flue test in accordance with national regulations should be carried out The appliance must not...

Page 35: ...s There are two methods of lighting the appliance Hand Set Infra Red and Manual Wall Switch this is an optional extra to order call 01325 327221 5 1 Using the Remote Control Handset see image The hand...

Page 36: ...tion sequence press Button 1 again STANDBY MODE o It is possible once the fire is lit to operate in standby mode with pilot only lit To do this press button 2 HIGH LOW FLAME o By pressing Button 3 inc...

Page 37: ...ton 1 again It is possible once the fire is lit to operate in standby mode with pilot only lit To do this press button 2 By pressing Button 3 the burner flame is increased to the maximum rate By press...

Page 38: ...helf taking care that the appliance will be hot The reset button is fitted next to the remote shield See Image Below Carefully insert hand below the shelf taking care not to touch any hot surfaces Pre...

Page 39: ...hs or so depending on usage Cleaning the Gas Fire Burner and Enclosure The most effective method of dust debris removal is achieved with the aid of a vacuum cleaner however great care must be taken to...