6.4 Final Checks before lighting the fire.
NOTE – REMOTE SYSTEM
The appliance is operated by 6 x “AA” batteries. It is advised that Lithium batteries
are used to increase life. The fire is supplied with a Handset and a Magic Eye. There is
the option to add a Manual Wall Switch. This must be fitted during installation. If this
has not been ordered then call 01325-327221 and request the part.
NOTE – APPLIANCE SEALED TO CHIMNEY CAVITY.
The enclosure must be sealed to the fireplace opening to create a closed system which
only allows air to be drawn from the room by the chimney. Take special care to ensure
there are no openings below the fireplace box where air can be drawn down the back
side of the enclosure and from the burner tray.
The Gather must be used.
NOTE – BURNER TRAY HOLES
The appliance is supplied with additional holes in the burner tray to allow gas pipe
access from various points. Once the gas pipe is fitted all other burner access points
must be covered using aluminium tape. Failure to do this may result in incorrect flame
activity and damage to the remote system. Any resulting damage caused by incorrect
installation is not covered by the warranty.
GAS LEAKS
With the isolation valve in the appliance switched off, test the gas line from the meter
to the appliance to ensure there are no gas leaks in the system. The appliance is
bubble tested at 150mBar before leaving the factory.
ROOM VENTILATION
The room must have an air vent in the room to provide a minimum of 100cm2 fresh air
from the outside?
BURNER VENTILATION
Has the fire been designed with burner air provided? See page 7.
NOTE - USING LPG BOTTLES
This is a high power fire and uses a high volume of gas. In very cold conditions LPG can
take longer to vent into gas and this may cause a drop in pressure which will shut the
appliance down. If this appliance is to be connected to LPG bottles it is recommended
that 2 x 47Kg bottles with a changeover valve is used. This must also include a
regulator.
WARNING: HEAT SHIELD.
IF THIS APPLIANCE IS OPERATED WITHOUT THE REMOTE HEAT SHIELD IN PLACE AND
SECURLY FITTED TO THE BURNER TRAY SERIOUS DAMAGE WILL OCCUR TO THE
REMOTE CONTROL SYSTEM.
ANY RESULTING DAMAGE WILL NOT BE COVERED BY CVO
FIRE AND IS NOT COVERED BY THE WARRANTY.