INSTRUCTIONS
•
Use the gas isolation valve to isolate the gas.
•
Taking care not to damage any components on the circuit board remove the heat
shield.
•
Note the position of the link in the circuit diagram.
•
Gently remove the link and replace this with the wall switch cable.
•
Route the cable as require ensuring that it is kept away from hot surfaces.
•
Secure the wall switch in the required place and connect the cable.
•
Refit the heat shield on the remote system.
•
Reconnect gas and check for leaks.
•
Review the section on “lighting the fire” to ensure the wall switch operates
correctly.
•
Operate the fire as normal.
VERY IMPORTANT NOTE
If the link “or” the wall switch is not fully connected to the remote the remote system will
not work.
To confirm:
THE LINK MUST BE FITTED
Or
THE WALL SWITCH MUST BE FITTED
CVO Fire will not accept any warranty claims resulting from damage caused by fitting or
removing the manual wall switch from the fire.