Page 14 of 42
•
TO TURN APPLIANCE “ON”
o
Press Button #1 & #2 at the same time and point directly at the magic eye. The
buttons must be held for 3-5 seconds. This is a child safe system to stop
accidental lighting. The ignition sequence will start. The gas to the pilot is
opened and the magnet unit pressed by the motor, the spark is generated. When
the pilot flame presence is detected (ionization flame control) the system holds
for 10 seconds to warm the thermocouple.
o
Once the thermocouple is warm enough to hold the magnet unit the valve will
allow gas to the burner at the maximum setting.
o
In case of failure during pilot ignition sequence, the EDB puts the system in safe
mode. To restart the ignition sequence press Button #1 again.
•
STANDBY MODE
o
It is possible once the fire is lit to operate in standby mode with pilot only lit. To
do this press button #2.
•
HIGH / LOW FLAME
o
By pressing Button #3 (increase) or Button #4 (decrease) the power output of the
appliance can be set between maximum and minimum levels.
o
By pressing Button #3 the burner flame is increased to the maximum rate.
o
By pressing Button #4 the burner flame can be reduced to the minimum rate.
•
TO TURN APPLIANCE “OFF”
o
To turn the appliance OFF Button #1 is pressed.
•
Each time a button is pressed a “beep” will be heard.
•
To Summarise:
o
Button #1 & #2 together – This switches the appliance ON.
o
Button #1 – This switches the appliance OFF.
o
Button #2 – This sets the unit into standby mode (pilot only)
o
Button #3 – This sets the flame at maximum rate.
o
Button #4 – This sets the flame at minimum rate.
•