3
ref: MA-ED-0008-EN-V16.0-MIÑO DESCALCIFICADOR D-DF-M3 & D-UF-M3.pdf
3. - GENERAL TECHNICAL CHARACTERISTICS.
Working pressures:
- Minimum pressure: 2,5 kg/cm²
- Maximum pressure: 6 kg/cm²
If the pressure is less than 2.5 Kg / cm² a pumping system must be installed to ensure the flow and pressure
required. If the pressure is greater than 6 Kg / cm² a pressure reducer must be installed.
Operating temperatures:
- The equipment should not be supplied with hot water (T> 36 ° C).
- The room temperature should be between 1-45 ° C.
Component materials:
- Valve: Reinforced Noryl.
- Bottle: Wound of reinforced polyester with fiberglass.
- Deposit: Made with P.E.
Resin:
- Softening cationic resin, regenerable with NaCl.
4. - ASSEMBLY, INSTALLATION.
4.1. - Previous warnings.
The softening systems D-DF and D-UF series
ARE NOT WATER PURIFYING SYSTEMS,
there only
purpose is to remove hardness.
If the water supply does not come from public supply network or is from an unknown origin,
performing a physical-chemical and bacteriological analysis will be necessary to ensure the proper functioning
of the water softener equipment, please contact your dealer so they can advise you in these circumstances.
The water supply must be suitably filtered, so installing sediment prefilter to facilitate the removal of
suspended particles in order to protect internal parts of the valve affecting its operation is recommended.
4.2. Installation.
The system operation can only be performed by technically qualified personnel.
Instalment requirements & recommendations:
4.2.1. Select the location of the instalment.
The adequate place where you choose to put the system must have easy access to access the
system and also to fill up the salt tank.
The system must be placed on a flat surface, protected from direct sunlight, rain and
humidity.
The system (including the overflow and drain lines) must be placed where the temperature is
not below 1ºC or above 49ºC.
The system mustn’t be installed near acid nor vapours, or be exposed to products derived
from petroleum, to avoid the risks of deflagration and explosion.
Summary of Contents for D-DF Series
Page 1: ...Water conditioning System SOFTENER D DF D UF Series INSTRUCTION MANUAL OPERATION MAINTENANCE ...
Page 23: ...23 ref MA ED 0008 EN V16 0 MIÑO DESCALCIFICADOR D DF M3 D UF M3 pdf 9 PARTS ...
Page 24: ...24 ref MA ED 0008 EN V16 0 MIÑO DESCALCIFICADOR D DF M3 D UF M3 pdf ...
Page 25: ...25 ref MA ED 0008 EN V16 0 MIÑO DESCALCIFICADOR D DF M3 D UF M3 pdf 10 DIMENSIONS Mm Inches ...