GETTING STARTED
base register address of the first channel. The base register address of the first channel is
selected by setting switches RS1, RS2 and RS3. (See Step 2.)
NOTE:
For a dual channel board, the configuration registers for both channels must be
programmed to operate correctly. Programming only the configuration registers of one
channel on a dual channel board may cause unpredictable results.
2.6.1 Register 25: Bus Connection Relay Control
Three bits in this register control relays that isolate the DTI-VME/S from the 1553 bus for
self-test, connect an internal termination resistor to the DTI-VME/S and select a direct or
transformer coupled connection to the bus. These selections are typically configured once
for a particular test setup. An additional bit in this register allows the machine controlling
the bit test pattern to output data continuously for diagnostic purposes.
MSB
LSB
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
LOOP T/D
CPL
INTRM
ISO
BUS
X X X X X X X X X X X X 1/0 1/0 1/0 1/0
Reserved
Bits 15-4 Reserved.
Bit 3
LOOP - Single/Continuous Loop Test.
This bit determines operation of a function that is controlled by writing to Register 18.
When a 1 is written to Bit 0 position of Register 18, a built-in test state machine pattern
generator sends a 1553 bus encoded message. The selection of one of two messages,
whether Bus A or B is used, and transmitter enabling is also done using bits in Register 18.
If this bit is set to 0, the test pattern is generated once for each write to Register 18. If this
bit is set to 1, one write to Register 18 enables a continuous output of the test pattern on the
bus at a very high rate. This output rate is useful for technician troubleshooting and is not
typically used in normal operations.
0 = Single test pattern output.
1 = Continuous looping test pattern output.
0 = Default.
Bit 2
T/D CPL - Transformer/Direct Coupling.
This relay can connect the DTI-VME/S to the 1553 bus in a direct or transformer coupled
configuration. Use direct coupling if the distance between the DTI-VME/S and the 1553 bus
measures 12 inches or less. Use transformer coupling if the distance between the DTI-
VME/S and the 1553 bus exceeds 12 inches, but not 20 feet. Direct coupling is applied
during the isolated internal self-test at powerup. After the self-test concludes, the bit is set
according to UUT connection requirements. The selected connection applies to Buses A and
B.
0 = Transformer coupling selected.
1 = Direct coupling selected.
1 = Default.
Bit 1
INTRM - Internal Termination.
Copyright 2004
2-5
DTI-VME/S
Summary of Contents for DTI-VME/S
Page 1: ...DTI VME S User Manual Document No T T MU DTXXVS A 0 A2 ...
Page 2: ......
Page 8: ...TABLE OF CONTENTS This page intentionally left blank Copyright 2004 iv DTI VME S ...
Page 28: ...GETTING STARTED This page intentionally left blank Copyright 2004 2 14 DTI VME S ...
Page 48: ...REGISTERS This page intentionally left blank Copyright 2004 3 20 DTI VME S ...
Page 76: ......
Page 77: ...8 INDEX INDEX Copyright 2004 INDEX 1 DTI VME S ...
Page 78: ......