![Cumberland INT-4807 Installation And Operation Manual Download Page 34](http://html1.mh-extra.com/html/cumberland/int-4807/int-4807_installation-and-operation-manual_2697971034.webp)
34
PNEG-1323
Integra Feed-Link
10. Display Unit Calibration and Setup
Display Unit Setup
NOTE: After installation, an EMPTY BIN and a
FULL BIN calibration must be performed.
Normal Display
The display unit will normally be displaying the
weight of the bin in pounds, kilograms, or
percentage. The display in normal mode will read
as follows depending on the units selected:
“Weight lbs nnnnn”, “Weight kg nnnnn”,
“Weight % nnnnn”, where nnnnn is a number.
NOTE: When entering or changing a parameter,
pressing the “CAL” key will abort
that operation.
Initial/Empty Bin Configuration
Press the UP and DOWN arrow buttons at the
same time to enter the initial configuration setup.
There are four (4) menu items in the setup mode:
empty bin calibration, units selection (kg, lbs, %),
the ID for this display on the RS485 network, and
re-init bin to reset to defaults. Once the setup
mode is entered, pressing the CAL button will
scroll to the next menu item. This is a one time
operation, and will only need to be done when
new load cells are installed.
The first menu item is: “Empty Bin 00000”
1. To calibrate the load cells with the empty bin
weight, make sure the bin is empty, and
press ENTER five times as the cursor scrolls
under each digit.
2. When an empty bin calibration has been
performed the display will return to the
normal display.
The second menu item is
:
“Units”
1. Press the UP and DOWN arrow buttons at
the same time to enter the initial
configuration setup, then press the CAL
button one time and this menu item will
appear on the screen.
2. Press the UP or DOWN arrow to select
whether the weight should be in pounds,
kilograms or percentage.
3. Once the desired units are selected, press
the ENTER button to save the selection. The
display will return to the normal display once
ENTER was selected.
Figure 10B Normal Display Screen
Figure 10C Empty Bin Display Screen
Figure 10D Units Display Screen