4. Load Cell Installation
PNEG-1323
Integra Feed-Link
15
Running Load Cell Cables
1. Label both ends of the load cell cable with
the load cell number. Numbers will range
from 1 through 8. Labeling the load cell
cables will identify what terminals to use
when connection wires to display unit
in
Installing Stand Alone Display Units on
. It will also expedite troubleshooting
if any problems should arise.
2. Run cable from load cell up bin leg using wire
ties (not included) to fasten into place. Run
cable along the cross brace to the center of
the bin. Then take cable around bin boot and
back up the leg that the display or junction
box is mounted to
and
3. Repeat
and
for each load cell.
Figure 4O
Fasten Wires with Wire Ties
Figure 4P
Run wire tie through holes in
bin legs to attach cable to legs
.
Figure 4Q
Run wires around the boot of the bin
.
Wire tie
Wire
Wire tie
Hole in leg
Load
cell
cable
Bin boot
Cross brace
Wire