Crystal Vision
Statesman
SYNNER-E 3G User Manual R1.2
70
10/09/2012
AES output routing
None (AES set to inputs)
Video gains
100%
Video lift
0%
De-embedder gains
0dB
AES input gains
0dB
Embedder pattern
SMPTE
Preset selection
Preset 1
GPI control of Presets
Disabled
GPO6 Alarms
Un-selected
Silence delay
0 seconds
Alarms
The GPO6 output is reserved for alarm indication and may have assigned any of the 38 video
and audio alarms.
Any number of alarms may be assigned to the GPI output, video missing and input groups
missing will assert an alarm immediately whereas the silence alarms can be assigned a delay
time to delay the time after which an alarm is asserted. This ability is especially useful to
prevent false alarming during quiet periods in the audio.
Where more than one alarm is flagged and an alarm condition is asserted, use the various
status indicators to determine the exact cause.
Visual indication of GPO6 status is provided on the board edge.
See Section 2.3 for further discussion of GPIs and pinout details.
Alarms