background image

DC-1023 

- 1 - 

8/6/2010 

  

 

 

Your best option for Proximity Access Control

 

 

 
 

SENTINEL-PROX DC-1023 

 
 

 

 

 

 

 

 

 

 

Dual frequencies RFID Reader 

 
 
 
 
 

Users Manual-041419 

 

 

 

 

 

Summary of Contents for Sentinel-Prox DC-1023

Page 1: ...DC 1023 1 8 6 2010 Your best option for Proximity Access Control SENTINEL PROX DC 1023 Dual frequencies RFID Reader Users Manual 041419 ...

Page 2: ...hese limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely ...

Page 3: ...tallation Practices 6 3 3 Metal Mounting 6 3 4 General Wiring Requirements 7 3 5 Power Supply 7 3 6 Grounding 7 3 7 Wiring Diagrams 7 4 INSTALLATION PROCEDURE 9 4 1 Parts List 9 4 2 Installation Steps 10 4 3 Verification 10 4 4 Mounting 10 5 WARRANTY 10 6 RETURN MATERIAL AUTHORIZATION RMA 10 7 TROUBLESHOOTING 11 8 PATENTS AND APPROVALS 12 NOTE READ AND USE THIS MANUAL NOTE FAILURE TO FOLLOW THE IN...

Page 4: ...DC 1023 4 8 6 2010 Your best option for Proximity Access Control REVISION HISTORY Version No Revised By Date Sections Affected Remarks 1 0 Z Wang 7 21 2010 All Initial version ...

Page 5: ... Permanently sealed electronics for indoor outdoor application o UV stabilized plastic housing 1 3 SUGGESTED APPLICATIONS o Access Control o Time Attendance o Asset Management o RFID 2 SPECIFICATIONS Input voltage 5V to 12 V Input current 150 mA typical Read range Smart Card ISO 14443 A B Up to 1 5 inches 3 8 cm Smart Labels ISO 15693 Up to 3 inches 7 6 cm Proximity Card 125KHz Up to 3 inches 7 6c...

Page 6: ...non interruptible power supplies AC switching relays light dimmers CRT s induction heater ultrasonic welder etc Do not bundle the reader wires together in one conduit with the AC power cables lock power and other signal wiring Keep all the Reader wiring at least 12 inches 30 cm away from all other wiring which includes but not limited to AC power computer data wiring telephone wiring and wiring to...

Page 7: ...ader When installing the Reader it is crucial to assure that the earth ground is the best ground available If you elect to use the AC main power ground conduct a test by measuring its resistance relative to a known good ground such as a cold water pipe or a structural steel that is in direct contact with the ground This resistance should be less than 50 ohms If you find that the AC main power does...

Page 8: ...DC 1023 8 8 6 2010 Your best option for Proximity Access Control Figure 1 Wiring Diagram for Wiegand Output Format Figure 2 Wiring Diagram for RS232 Output Format ...

Page 9: ...232 Output Format 4 INSTALLATION PROCEDURE Check to verify that every item listed under Section 5 1 of this manual is present before starting the installation 4 1 PARTS LIST a Installation sheet P N xxx xx x QTY 1 b Sentinel Prox DC 1023 Reader P N xxx xx x QTY 1 c 6 32x1 Machine screw P N 0616MPP QTY 1 ...

Page 10: ...by placing the card in front of the reader after the LED turned RED If the Panel did not right it must be powered off on to re initialize 4 4 MOUNTING 1 Connect the remaining wires to the Panel 2 Mount the Reader securely to the electrical junction box with 6 32x1 machine screw Item c on Parts List 3 Install the Snap On cover 5 Warranty AWID s products are warranted to the original purchaser to be...

Page 11: ...way from electromagnetic interference sources When troubleshooting try to identify the source of the problem to a unit level Is the problem originating from the panel Or is the problem originating from the Reader Maybe the problem is the power supply All AWID s readers will need only a power supply and a valid card to work properly If the reader is only connected with RED 5 12V and BLACK Ground an...

Page 12: ...100 from 8 00 a m to 5 00 p m Pacific Time GMT 8 hrs 8 Patents and Approvals AWID products are covered by United States patent 5594384 AWID logo is a registered trademark of Applied Wireless Identifications Group Inc Where required AWID s products are approved by the appropriate regulatory agencies U S Federal Communications Commission Part 15 Underwriter Laboratory Designed to Comply with CE UL V...