Crystal Vision
Using the front control panel
SYNNER-E 3G User Manual R1.2
48
10/09/2012
channel silence
present.
De-embedder
Group 2 audio
channel silence
Rotate the shaft control to view de-embedder group 2 channel
status.
1234
=channel not silent,
s=silent
,
m
=missing,
dd
= Dolby E
present.
De-embedder
Group 3 audio
channel silence
Rotate the shaft control to view de-embedder group 3 channel
status.
1234
=channel not silent,
s=silent
,
m
=missing,
dd
= Dolby E
present.
De-embedder
Group 4 audio
channel silence
Rotate the shaft control to view de-embedder group 4 channel
status.
1234
=channel not silent,
s=silent
,
m
=missing,
dd
= Dolby E
present.
AES input channel
silence
Rotate the shaft control and press F1.
AES input 1&2
silence
Rotate the shaft control to view the AES input 1&2 status.
LRLR
=channel not silent,
mm
=missing,
ss
=silent,
dd
= Dolby E
present.
AES input 3&4
silence
Rotate the shaft control to view the AES input 3&4 status.
LRLR
=channel not silent,
mm
=missing,
ss
=silent,
dd
= Dolby E
present.
AES input 5&6
silence
Rotate the shaft control to view the AES input 5&6 status.
LRLR
=channel not silent,
mm
=missing,
ss
=silent,
dd
= Dolby E
present.
AES input 7&8
silence
Rotate the shaft control to view the AES input 7&8 status.
LRLR
=channel not silent,
mm
=missing,
ss
=silent,
dd
= Dolby E
present.
Video control menu
From the STATUS top menu, rotate shaft control to select the Video control menu. Press F1
and then rotate the shaft control to access the two video control menu options. These options
are: - video time, video gain and optical input selection. To enter a sub menu once selected,
press F1 and use the shaft control to traverse the sub menu.
Menu
Description
Video source
Rotate the shaft control and press F1.
Video input source
Rotate the shaft control to view the video input source.
Press F1 and rotate the shaft control to select.
BNC, Optical.
Mode selection
Rotate the shaft control to view the mode selection.
Press F1 and rotate the shaft control to select.
Synchroniser, Delay.
Synchroniser
override
Rotate the shaft control to view the synchroniser override.
Press F1 and rotate the shaft control to select.
Normal, Over Ride.
Output freeze
Rotate the shaft control to view the output freeze selection.
Press F1 and rotate the shaft control to select.
Off, Frame, Black Matte, Blue Matte.
On loss of input
Rotate the shaft control to view the On loss of input selection.
Press F1 and rotate the shaft control to select.
Last Frame,