Crystal Vision
Hardware installation
SYNNER-E 3G User Manual R1.2
19
10/09/2012
2.3 General Purpose Interface (GPI)
Each frame slot has up to six connections ‘a-f’ for GPI control and monitoring. These
connections are available at the rear of the frame on the 26-way D-Type remote connectors.
GPI
Low (<1V)
High (+5V)
1
‘a’
Recall preset bit 1
See following table for user preset control
2
‘b’
Recall preset bit 2
3
‘c’
Recall preset bit 4
4
‘d’
Recall preset bit 8
5
‘e’
6
‘f’
Alarms (
See alarm table)
Alarm condition
No alarm
As supplied, each GPI output has a 270
Ω
resistor in series with its output. This allows for an
external LED to be driven, connected to a DC voltage of +5V.
Each General Purpose Input (GPI) is fitted with a 6800
Ω
resistor connected to the internal
+5V.
The 16 user preset configurations can be recalled using binary notation.
GPI
Bit 8
Bit 4
Bit 2
Bit 1
GPI
Bit 8
Bit 4
Bit 2
Bit 1
Preset
Preset
1
0 0 0 0
9
1 0 0 0
2
0 0 0 1
10
1 0 0 1
3
0 0 1 0
11
1 0 1 0
4
0 0 1 1
12
1 0 1 1
5
0 1 0 0
13
1 1 0 0
6
0 1 0 1
14
1 1 0 1
7
0 1 1 0
15
1 1 1 0
8
0 1 1 1
16
1 1 1 1
GPI out 6 (f) can be configured to be asserted for a selection of error conditions. The
following table lists the conditions to be selected from.
Reportable error conditions
Video Missing
Silence AES 6
Reference Missing
Silence AES 7
Input group 1 Missing
Silence AES 8
Input group 2 Missing
Dolby E on Input Group 1 Channel 1&2
Input group 3 Missing
Dolby E on Input Group 1 Channel 3&4
Input group 4 Missing
Dolby E on Input Group 2 Channel 1&2
Silence on Group 1 Channel 1&2
Dolby E on Input Group 2 Channel 3&4
Silence on Group 1 Channel 3&4
Dolby E on Input Group 3 Channel 1&2
Silence on Group 2 Channel 1&2
Dolby E on Input Group 3 Channel 3&4
Silence on Group 2 Channel 3&4
Dolby E on Input Group 4 Channel 1&2