79
6. Network Environments
It is required to follow the recommendation of the environments where S-160 will be installed or the
similar environments
.
5-1. Private line
Environment
Usually Company, University, Research center uses the leased line. They use many public IP addresses. In
order to install S-160 under this environment, select “Static IP Address” in ‘
Static IP Setting
’ of ‘
3. Basic
setting
’ and input IP address, subnet mask and gateway. If there is DHCP server on the network, select
‘Dynamic IP Address’ in ‘
Dynamic IP
’ of ‘
3. Basic Setting
’. You can get all the information (IP address, subnet
mask, gateway, DHCP server) from the network administrator. Sometimes, the S-160 may
not work
properly if the user installed firewall for security purpose. In this case, open the port on the S-160, then it will
work properly. You can check the current port of S-160 from the “Administrator's Page”->”Network Setting”-
>”Port Setting” (see ‘
3. Basic Setting
‘). The default port is set on ex-factory as follows :
¾
Web Connection Port: Port 80 TCP
¾
Authentication and Control Port: Port 9000 TCP
¾
Video Streaming Port: Port 9001 TCP
¾
1 way Audio Port: Port 9002 TCP
¾
2 way Audio Port : Port 9003 TCP
5-2. Broadband (ADSL, Cable, Fiber Optic) Modem Environment
Home, store, small office use one Broadband modem (DSL, Cable Modem), and use one public IP address
normally. In order to use several PC through one Public IP address, the user in most cases use IP sharing
device. We recommend using an IP router (IP Sharing device) to install the S-160. There may be a case in
no need of router, but most people use S-160 and other PC 1set or more. When using the router, connect
the router and input IP address of S-160 (IP address of S-160 is set as 192.168.1.8 on ex-factory) in DMZ
menu. If the user cannot use the DMZ function because there is no DMZ menu in the router or some other
reasons, go into port forwarding or NAT menu on the router and map the port of S-160 one by one. User can
check the current port setting of S-160 from “Administrator's Page”->”Network Setting”->”Port Setting” (see
‘
3. Basic Setting
‘). Manufacturer’s setting of S-160 is as follow on ex-factory : (The user can change port if
necessary).
¾
Web Connection Port : Port 80 TCP
¾
Authentication and Control Port
: Port 9000 TCP
¾
Video Streaming Port
: Port 9001 TCP
¾
1 way Audio Port : Port 9002 TCP
¾
2 way Audio Port : Port 9003 TCP
Summary of Contents for S-160
Page 1: ...1 Network A V Server S 160 User s Manual Version1 0 ...
Page 6: ...6 1 Feature ...
Page 9: ...9 2 Installation and Video Check ...
Page 15: ...15 3 Basic Setting ...
Page 27: ...27 4 Expert Setting ...
Page 29: ...29 Pic 4 2 Administrator s Page ...
Page 48: ...48 5 Basic Use ...
Page 78: ...78 6 Network Environments ...
Page 80: ...80 7 Appendix ...