Appendix C. Troubleshooting
Guide
Doc.#6000-0015 Rev: A
Page 53
Appendix C. Troubleshooting Guide
Troubleshooting Flow Diagram
If you have the following
trouble
Check the following things
Notes
PC ComWare does not run.
Verify that system requirements
are met.
Verify proper installation of PC
ComWare.
Verify SIO Configurator is not
running.
PC ComWare application
crashed.
Reset the PC Radio, reset the
Node, and restart the application.
Desired Bluetooth address
not seen by PC ComWare.
Check Node power.
Check PC radio function.
Verify Node is within range of PC
radio.
Verify Node is not in use with
another host.
Repeat the Inquiry by clicking on
Locate Nodes.
Check if the Comm Port
assignment is correct.
Restart the Application, reset the
PC Radio and reset the Node.
LT110 does not locate and
Nodes on Inquiry
Verify that the PCMCIA led flashes
during the Inquiry command.
Verify that the patch software has
been installed.
Verify that the correct Comm port
has been selected.
Node connection/power lost.
Reset the Node and re-establish
the connection by clicking on
Locate Nodes.
No sensors show up in the
sensor table in PC ComWare.
Verify that the SIO is connected to
the node.
Sensor TEDS data is not
correct.
Verify that the TEDS in the SIO is
programmed for the sensor
connected to the SIO.
Verify proper TEDS programming
in SIO configuration program.
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]