background image

Control System 

 

Crestron 

Lighting

 

Basic Lighting System Interconnections   

A Crestron Lighting System 

 

30  

  Lighting Control System Design 

Design Guide – DOC. 5999A 

Summary of Contents for Lighting Control System

Page 1: ...Crestron Lighting Control System Design Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2003 Crestron Electronics Inc ...

Page 3: ...Step 2 Module Selection 8 Step 3 Enclosure Selection 12 Step 4 User Interface Selection 14 Step 5 Wiring Plan 23 Step 6 Control Processor Selection 24 Step 7 Network Block Selection 28 Step 8 Accessories Selection 29 Basic Lighting System Interconnections 30 Ordering a Crestron Lighting Control System 31 Hardware 31 Programming 31 Example Lighting System 32 Merchandise Returns Repair Service 38 CR...

Page 4: ......

Page 5: ...o control security HVAC and audio video systems The system control can be located near the user interface the controlled circuits or can be centralized at some other remote location Crestron D3 Pro software is a comprehensive design and development tool that provides a programming environment for all lighting HVAC and security needs It contains many features to facilitate a successful installation...

Page 6: ...l processor connected via a local area network to the lighting modules and the user interfaces is dedicated to lighting fans motors HVAC and security Other processors that are dedicated to other home control systems can communicate via Ethernet RS 232 or RS 422 to the lighting processor This eliminates the need for additional controls for other home systems separating home safety and life support ...

Page 7: ...wiring a low voltage communication wire is run from the dimmer to the nearest Cresnet connection This design offers the end user the familiarity of a traditional control coupled with the power and flexibility of automated control In a distributed design the user has the security of operating the lighting in the event of a temporary control system interruption Lighting Layout in a Distributed Desig...

Page 8: ...trolled using the astronomical time clock or whole house presets This level of control requires connection to a central dimming controller Each room is equipped with a low voltage keypad for preset selection and audio video integration All the dimmers in the system grouped into the central controller for wiring convenience communicate with each other through the Crestron control system providing a...

Page 9: ...panels the control processor details large systems should use a dedicated lighting control processor and the optional window treatment details which include shade blind motors and relay control consult manufacturer for details The following eight steps performed in this sequence is the recommended design procedure Step 1 Define the Load Schedule A load schedule lists the information on each load c...

Page 10: ...oad Type of the controlled lighting zone Load types include incandescent magnetic low voltage electronic low voltage neon cold cathode HID dimmable non dimmable fluorescent ballast ceiling fans and switched 3 wire motor circuits This information is especially important for selecting the correct Crestron module power rating and type 5 Dimming requirement for the controlled lighting zone i e whether...

Page 11: ...owing steps Once all the steps are completed a complete bill of material for the system is created The seven steps are as follows Module selection based on the number and type of loads Enclosure selection based on the number of modules and locations User interface selection based on the user control requirements Wiring plan based on the previous steps and the layout of the environment Control proc...

Page 12: ...lock in the enclosure Terminal rails and blocks do not occupy a module space within an enclosure Oversized heat sink fins on the face of the module provide superior heat dissipation eliminating heat related failures The modules incorporate spit bobbin transformers and ground reference electronics for superior performance AC line noise interference and lamp flicker are eliminated by an innovative z...

Page 13: ...re Range 32 104 F Humidity Range 10 90 RH non condensing Weight 3 lbs CLX 1DIM8 is best used for multiple small incandescent loads It is economical to use only six or seven channels on the module with small loads while leaving some channels unconnected The single input feed limits the total output of all eight controlled dimmer circuits to 1920 watts 16A CLX 1DIM8 Module Specifications Load Type I...

Page 14: ...e Size H x W x D 7 3 8 x 6 7 8 x 3 Temperature Range 32 104 F Humidity Range 10 90 RH non condensing Weight 3 lbs The CLX 1MC4 controls up to four 10A HP maximum bi directional motors High voltage window treatment motor controls are assigned to CLX 1MC4 The single input feed limits the total output of all eight controlled dimmer circuits to 1920 watts 16A CLX 1MC4 Module Specifications Load Type 3...

Page 15: ... a test point and interface to the lighting module Bypass jumpers on the terminal block allow the testing of circuits and protect the module during installation Left and right wiring labels are provided with each terminal block The wiring labels are positioned in between the terminal block and enclosure to provide identification of each terminal block section The left side labels are common for bo...

Page 16: ...enclosure size Consider selecting enclosures with excess room to accommodate system improvements and expansion Crestron recommends selecting an enclosure that has at least one more space than needed allowing for changes in modules or lighting fixtures A larger enclosure also enhances air cooling The CAEN 7x2 is the largest and most economical enclosure containing up to 12 modules and a PAC2 proces...

Page 17: ...ries Dimensions Front and Side Views CAEN Dimensions 1 7x2 7x1 4x2 4x1 2x1 H1 62 38 23 H2 2 11 16 2 H3 56 32 34 18 W1 26 15 26 15 W2 25 14 25 14 W3 2 1 2 1 W4 20 10 20 10 W5 5 20 9 20 9 W6 2 2 2 2 D1 4 Cover Thickness 1 16 Cover Height 62 39 24 Cover Width 27 16 27 16 Weight 2 Empty 3 65 42 43 28 19 D1 W3 H1 W6 W5 H3 W3 W3 W4 W1 W2 H2 Weight Full 4 155 88 95 55 31 1 Length is in inches 2 Weight is...

Page 18: ...art of a Crestron solution The panels are standard Cresnet devices providing fingertip control when the control system is properly programmed using Crestron s SIMPL Windows Application Builder or D3 Pro software The number in the product s name corresponds to the number of buttons on the panel Each of these panels is available in three colors almond black and white A letter at the end of the produ...

Page 19: ...View of the C2N DB Wall Panel 1 53 in 3 89 cm 1 07 in 2 72 cm 1 79 in 4 55 cm 4 16 in 10 57 cm 1 67 in 4 24 cm 2 70 in 6 86 cm Rubber with buttons removed Front View Cresnet port Back View with buttons installed Side View Membrane Design Guide DOC 5999A Lighting Control System Design 15 ...

Page 20: ...ng features Available with 2 4 6 8 or 12 buttons Colors include white almond or black Metal faceplate options Black Chrome Brushed Gold Polished Black Polished Gold Polished Brass Stainless Steel Primed faceplate available All keypads can be custom engraved All keypad buttons are backlit capable and have an LED that serves as a user feedback indicator Status LEDs are controlled via SIMPL programmi...

Page 21: ...ircuit application It does not connect to a Cresnet system and cannot be used without a CLW DIMS The CLW SLVD does not have a mode selection switch and is not programmable It emulates the operation of the CLW DIMS to which it is connected The CLW DIM CLW DIMS and CLW SLVD are available in white designated by part numbers ending in W almond designated by part numbers ending in A and black designate...

Page 22: ...le provides the derating information for this application Application No Heat Sink Removed Single Unit One Heat Sink Removed Two Gang Both Heat Sinks Removed Three or more Gang Incandescent and Tungsten Halogen 1000 W 800 W 600 W 450 W 400 W 300 W Magnetic Low Voltage 1000 VA 750 W 800 VA 600 W 600 VA 450 W 450VA 300 W 400 VA 300 W 300 VA 200 W For additional installation information refer to the ...

Page 23: ...Crestron Lighting Control System Physical View of CLW SLVD clockwise from top Top Side and Front Design Guide DOC 5999A Lighting Control System Design 19 ...

Page 24: ...ed by part numbers ending in A and black designated by part numbers ending in B These switches can be covered with a decorative faceplate not supplied CLW SW CLW SWS CLS SLVS Specifications SPECIFICATION DETAILS Power Requirements Line Power 120 VAC 60 Hz Switch Type Single Pole Single Throw Load Type Incandescent Tungsten Halogen Fluorescent Electronic Low Voltage Magnetic Low Voltage General Pur...

Page 25: ...c 6134 for derating information in multi gang applications available on the Crestron website www crestron com Physical View of CLW SW SWS clockwise from top Top Side and Front Physical View of CLW SLVS clockwise from top Top Side and Front Design Guide DOC 5999A Lighting Control System Design 21 ...

Page 26: ...e of Crestron lighting systems The designer can create a complex control environment while presenting the user with easy and intuitive controls For example a Good Night button can be programmed to dim the lights gently quiet the music notify the alarm system and set a nighttime temperature All with one touch Designed using VT Pro e software these user interfaces can be customized to provide comple...

Page 27: ... Wiring Plan The wiring plan includes all enclosures and the interconnecting wiring The designer determines the location of the enclosure s the route of keypad and touchpanel connections to the enclosure s the route of the interconnecting cable from the processor to the other enclosure s and the high voltage load routes to the enclosure or dimmer Ensure there are enough connectors and power PAC2 o...

Page 28: ... DIMS Room 4 DIM6 Wall dimmer 200 Watts CLW DIM Room 5 DIM7 Wall dimmer 120 Watts CLW DIM Room 5 KP1 Wall Keypad Fan Motor Speed CLX 1FAN4 Step 6 Control Processor The PAC2 has been specifically designed for the Crestron automation enclosure and the Crestron lighting system although other Crestron processors can also be used The PAC2 can be placed in its own enclosure for simplification of low vol...

Page 29: ... C2N SPWS300 is capable of delivering a nominal 75 watts of power at 24 volts DC on any of its eight channels The PAC2 connects all the user interfaces Keypads and wall switches touchpanels contact closures emergency switches override switches backup Cresnet controller input output relays fault indicator computer data port The PAC2 enables the customer to efficiently control not only the lighting ...

Page 30: ... back up processor and emergency override closure signals In the absence of Cresnet or in case of a power failure a signal is generated to switch power and communication of the Cresnet system to a back up processor When the override connection receives a contact closure a signal is passed to the lighting modules via the fifth wire of the interconnect cable and the lights are turned on to a program...

Page 31: ...mable digital analog inputs digital outputs 8 Normally open isolated relays MOV suppression 4 Internal and External power 2 External contact closure 1 External 2 Series control system backup 1 To external 2 Series control system for fault indication 2 Lighting module interface Power Requirements 100 240 VAC 2 4 A 50 60 Hz Internal Universal Power Supply Network Power Fuse Rating 4 A 250 V 1 x Slow...

Page 32: ...he incoming Cresnet line Verify that the incoming Cresnet line has sufficient power for all connected devices Two OVERRIDE ports are activated from dry closure switches When a switch contact closure is received between the G connection and the L or R connections the respective left or right column of modules will set the lights to the programmed override state CAEN BLOCK OVER RIDE G L R CAEN BLOCK...

Page 33: ...ical codes Additional CAEN enclosures can be used with CAEN UMP plates s to facilitate any required separation codes CAEN UMP is available in a variety of sizes and occupies the same area as one two or four Crestron lighting modules Plate size corresponds to the number of module spaces and their arrangement within the enclosure CAEN UMP Series Specifications Shown with a CAEN 7x2 enclosure CAEN UM...

Page 34: ...Control System Crestron Lighting Basic Lighting System Interconnections A Crestron Lighting System 30 Lighting Control System Design Design Guide DOC 5999A ...

Page 35: ...control system with the Crestron D3 Pro System Programming software package or with SIMPL Windows for the more advanced Cresnet programmers Crestron D3 Pro Software provides all the tools necessary to create a complete Crestron Lighting System for residential applications The lighting system includes the control system program touchpanel screens and keypad programming documentation and real time l...

Page 36: ...Control System Crestron Lighting Example Lighting System This example is based on the following typical wiring plan 32 Lighting Control System Design Design Guide DOC 5999A ...

Page 37: ...lights Incandescent yes no 100 3 300 Main Floor Bathroom 2 Drapes 021 Drapes 3 Wire Motor no no 200 1 200 Main Floor Bathroom 2 Exhaust Fan 012 Exhaust Fan Switched no no 200 1 200 Main Floor Bedroom Ceiling Fan 022 Ceiling Fan Ceiling Fan no no 100 1 100 Main Floor Bedroom Downlights 005 Downlights Incandescent yes no 250 2 500 Main Floor Bedroom Downlights 2 004 Downlights Incandescent yes no 10...

Page 38: ...eiling Fan 022 Ceiling Fan Ceiling Fan no no 100 1 100 Enclosure 1 6 CLX 1FAN4 1 Main Floor Bedroom Downlights 005 Downlights Incandescent yes no 250 2 500 Enclosure 1 2 CLX 1DIM8 7 Main Floor Bedroom Downlights 2 004 Downlights Incandescent yes no 100 4 400 Enclosure 1 3 CLX 1DIM4 1 Main Floor Bedroom Downlights 3 003 Downlights Incandescent yes no 100 1 100 N A N A Interface 6 1 Main Floor Bedro...

Page 39: ...Crestron Lighting Control System Circuits and Interfaces Design Guide DOC 5999A Lighting Control System Design 35 ...

Page 40: ...Control System Crestron Lighting 36 Lighting Control System Design Design Guide DOC 5999A Module Wiring ...

Page 41: ...Crestron Lighting Control System PAC2 Connections Design Guide DOC 5999A Lighting Control System Design 37 ...

Page 42: ...t lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been...

Page 43: ...Crestron Lighting Control System This page intentionally left blank Design Guide DOC 5999A Lighting Control System Design 39 ...

Page 44: ...Crestron Electronics Inc Design Guide DOC 5999A 15 Volvo Drive Rockleigh NJ 07647 11 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Reviews: