Crestron
e-control Vote SW-VOTE
82
••
Appendices
Installation & Reference Guide — DOC. 5822
AgendaTrigger
Voting Console
Description
Agenda item has been set
Direction
Voting Computer to control system
Type
Digital
Value
Pulse
Expected Reply
Start
or
Abort
Comments
This signal is pulsed when a valid agenda item has been selected or entered either
from the Voting Computer interface or from the Control System Interface. It is
utilized by the control system to indicate the state of the voting sequence through
screen button feedback or by enabling/disabling certain screen buttons. An
example of the use of this signal is provided in demo2.
Used in conjunction with the “state” signals,
StateStart, SateEnd, StateDisplay,
and
StatePrintSave
; and the other pulsed signal,
NewVote
. These signals provide
feedback to the control system about the voting sequence. They can be used to
highlight the sequence control buttons, or to enable/disable specific touchpanel
choices. (See “State Coordination,” page 61, for a “score sheet” illustrating the
sequence.)
See Also
SetAgenda, Start, Abort