Crestron
DM-RMC-100-C
DigitalMedia 8G+ Receiver 100
Operations & Installation Guide – DOC. 7000C
DigitalMedia 8G+ Receiver 100: DM-RMC-100-C
17
NOTE:
Ensure that the unit is properly grounded by connecting the chassis ground
lug to an earth ground (building steel).
NOTE:
For DM 8G+ wiring, use Crestron DM-CBL-8G DigitalMedia 8G cable,
Crestron DM-CBL DigitalMedia cable, Crestron DM-CBL-D DigitalMedia D cable,
or generic CAT5e (or better) UTP or STP. Maximum wire length for DM 8G+ is 330
feet (100 meters) between devices. Shielded cable and connectors are recommended
to safeguard against unpredictable environmental electrical noise which may impact
performance at resolutions above 1080p. Refer to the latest version of the Crestron
DigitalMedia Design Guide (Doc. 4546) for complete system design guidelines.
DM 8G+ is also compatible with HDBaseT Alliance specifications for connecting to
HDBaseT compliant equipment.
NOTE:
The 24 Vdc power pack (included) is not required if power over DM or
power over HDBaseT is used.