Crestron
DM-RMC-100-C
DigitalMedia 8G+ Receiver 100
Operations & Installation Guide – DOC. 7000C
DigitalMedia 8G+ Receiver 100: DM-RMC-100-C
23
USB Communication via DM Switcher
To establish USB communication between the PC and the DM switcher:
1. Use the Address Book in Crestron Toolbox to create an entry using the
expected communication protocol (USB). When multiple USB devices are
connected, identify the DM switcher by entering “DM-MD8X8”,
“DM-MD16X16”, or “DM-MD32X32” in the
Model
textbox, the unit’s
serial number in the
Seria
l textbox, or the unit’s hostname in the
Hostname
textbox. The hostname can be found in the “System Info” window in the
section marked
Ethernet
; however, communications must be established in
order to see this information in the “System Info” window.
2. Display the “System Info” window (click the
icon); communications
are confirmed when the device information is displayed.
Via LAN Port
TCP/IP Communication via LAN Port of DM-RMC-100-C
To establish TCP/IP communication between the PC and the DM-RMC-100-C via
the
LAN
port of the DM-RMC-100-C:
1. Use the Device Discovery Tool in Crestron Toolbox to find the IP address
of the DM-RMC-100-C. The tool is available in Toolbox version 1.15.143
or later.
NOTE:
When the DM-RMC-100-C is used in a standalone configuration
(not used with a DM switcher), DHCP is enabled by default. If desired, a
default IP address (192.168.1.243) can be assigned by holding down its
SETUP
button while applying power. This IP address overwrites any
previous settings and remains until it is changed.
2. Use the Address Book in Crestron Toolbox to create an entry for the
DM-RMC-100-C using the
TCP
connection type, and enter the IP address
of the DM-RMC-100-C.
3. Display the “System Info” window of the DM-RMC-100-C (click the
icon); communications are confirmed when the device information
is displayed.