Digital Audio Processor
Crestron
C2N-DAP8
48
•
Digital Audio Processor: C2N-DAP8
Operations Guide - DOC. 8186
File Transfer | Send Program Command
3. The “Send Program” window appears, as shown after this step. Click
Browse
, locate the compiled file (.spz) and click
Open
. This will
display the program's header information and enable one or both of the
What to Send
check boxes. If the program does not contain any
SIMPL+ modules, only the
SIMPL Program
check box will be enabled.
If it does contain SIMPL+ modules, then the
SIMPL+
Program
(s)
check box will also be enabled. Select one or both check boxes and
then click
Send Program
to begin the transfer.
NOTE:
Refer to the respective Operations Guide for the control system for details
about the other fields shown on the “Send Program” window.
“Send Program” Window
4. To verify that the program has been transferred successfully, select
Diagnostics
|
Report Program Information
. This should display a
window that provides details about the current program loaded into the