Chapter 7 How to Use a Multimeter
©2017 by Crafco, Inc. All Rights Reserved………………..…………………………………..….…How to Use a Multimeter 7-2
7.4 Checking Amperage
The Multimeter can be used to check amperages under 10 amps in AC or DC current.
When checking the amperage of the electric hose
always use a clamp-on amp meter
. (See
7-2 Clamp – On Amp Meter/Multimeter
) The amperage in the hose can reach as high as 35 amps.
Clamp the meter around one wire at a time. Remember most clamp-on meters do not work on DC
current.
Fig. 7-1 Standard Multimeter
AC Voltage ~
• Generator Output
Audible Continuity
• Hose, Wand, and
wire connection
Ohms
Ω
• Sensors
• Hyd. Coils
•
Burner Ignition
Coil
Use these ports. Do not
use the fuse port, it is for
amps