Super Shot 125 Diesel Melter Part Manual
Chapter 9 Troubleshooting (47400)
©2017 by Crafco, Inc. All Rights Reserved………………...…………………………………Troubleshooting (47400) 9-1
9.0 Troubleshooting (47400)
9.1 Diesel Burner Troubleshooting
Symptom: Burner will Not Ignite
9.1.1
Step
Possible Cause
If . . .
1
Start Troubleshooting at the control box. Is
the Isuzu engine running?
•
Yes, go to Step 2.
•
No, start the Isuzu engine.
•
Note
:
You can troubleshoot the burner
without the engine running, but you must
connect a battery charger to the battery and
the ignition must be in the “ON” position.
2
Is the “Main Power” switch in the “ON”
position?
•
Yes, go to Step 3.
•
No, turn the toggle switch to the “ON”
position.
3
Is the “Burner ON/OFF toggle” switch in
the “ON” position?
•
Yes, go to Step 4.
•
No, turn the toggle switch to the “ON”
position.
4
Are both the Material and Hot Oil
temperature dials set to proper operating
temperatures?
•
Yes, go to Step 5.
•
No, set the Material according to the type of
sealant you are using and the Hot Oil 100°F
above the Material set point.
5
Are both the Material and Hot Oil
temperature displays reading a three digit
positive number?
•
Yes, go to Step 6.
•
No, go to
6
Is the red "Burner" light "ON"?
•
Yes, go to Step 7.
•
, Step 4.
7
Is the diesel tank full?
•
Yes, go to Step 8.
•
No, fill your tank or make sure you have
enough fuel for the day.
8
Did you run the diesel tank low on fuel or
empty?
•
Yes, you need to bleed your burner, go to
Table 9-12 Bleeding the Diesel Burner
•
No, go to Step 9.
Table 9-1 Basic Visual Troubleshooting