Super Shot 125 Diesel Melter Part Manual
Chapter 8 Troubleshooting (43600, 43800 and 45500)
©2017 by Crafco, Inc. All Rights Reserved………………...……………Troubleshooting (43600, 43800, and 45500) 8-34
Step
Possible Cause
If . . .
10d
Is there 12 Vdc between the "Mixer" toggle
switch center post red wire and the blue (4) wires
ground din plug?
• Yes, check for a broken wire or poor wire
crimp on the red wire between the "Mixer"
toggle switch and the "Pump" toggle switch.
• No, if this is the case you would have had an
agitator problem. Call Crafco, Inc. and speak
to a service technician.
10e
Unscrew the din plug center screw so you can
pull the din plug up about 1/4", so you can check
for voltage. Is there 12 Vdc from side post to side
post, when the wand trigger is pulled?
• Yes, the electrical system for the agitator is
• No, recheck the amber light, if the light comes
"ON" and you do not have 12 Vdc then
replace the din plug.
Table 8-30 Pump Electrical Troubleshooting (continued)