Filac

 

 3000 EZ/EZA Electronic Thermometer

12

Table of Contents

XI.  Warranty

Limited Warranty:

 

Covidien warrants to the original purchaser (“Customer”) that this product will be free of defects in materials and 

workmanship, under normal use, for three (3) years from the date of original purchase from Covidien or its authorized distributor. If 
this product does not operate as warranted above during the applicable warranty period, Covidien may, at its option and expense, 
replace the defective part or product with a comparable part or product, repair the defective part or product, or, if neither 
replacement nor repair is reasonably available, refund to Customer the purchase price for the defective part or product. Dated proof 
of original purchase will be required.
Covidien does not assume any liability for loss arising from unauthorized repair, misuse, neglect, or accident.  Removal, defacement, 
or alteration of serial lot number voids warranty.  Covidien disclaims all other warranties, expressed or implied, including any implied 
warranty of merchantability or fitness for a particular purpose or application other than as expressly set forth in the product labeling. 

Section XII – Electromagnetic Conformity Declaration

The Filac 3000 Electronic Thermometer has been build and tested according to IEC 60601-1, CAN/CSA C22.2 No. 60601-1-08 and EN 
60601-1-2 Standards.

Guidance and manufacturer’s declaration – electromagnetic emissions

The FILAC 3000 Electronic Thermometer is intended for use in the electromagnetic environment specified below. The user of the FILAC 
3000 Electronic Thermometer should assure that it is used in such an environment.

Emissions Test

Compliance

Electromagnetic Environment - Guidance

RF emissions 
(CISPR 11)

Group 1

 The FILAC 3000 Electronic Thermometer uses RF energy only 
for its internal function. Therefore, its RF emissions are very 
low and are not likely to cause any interference in nearby 
electronic equipment.

RF emissions 
(CISPR 11)

Class B

The FILAC 3000 Electronic Thermometer is suitable for use in all 
establishments, including domestic establishments and those 
directly connected to the public low-voltage power supply 
network that supplies buildings used for domestic purposes.

Harmonic emissions 
(IEC 61000-3-2)

Not applicable

Summary of Contents for Filac 3000 EZ

Page 1: ...Table of Contents Filac TM 3000 EZ EZA Electronic Thermometer Operating Manual...

Page 2: ...Filac 3000 EZ EZA Electronic Thermometer Operating Manual...

Page 3: ...ectal Temperature Taking 5 Direct Mode 6 Direct Mode Lock 6 Recall Last Temperature 6 VI Cleaning and Sterilization 6 VII Battery Replacement Installation 7 VIII Troubleshooting 7 IX Specifications 8...

Page 4: ...urement and Regulation Plenum Press NY 1982 p 81 87 II General Information 1 The Filac 3000 EZ EZA Electronic Thermometer is a fast highly accurate and easy to use clinical instrument for measuring pa...

Page 5: ...not open unit No user serviceable parts inside Opening of device may affect calibration and voids warranty 11 Disposal of used probe covers must be performed in accordance with current medical practic...

Page 6: ...limitations 10 95 Temperature limitations 13 F 25 C 131 F 55 C Follow instructions for use This manual must be read prior to use of the thermometer Symbol appears blue on device Non ionizing electroma...

Page 7: ...mbersand Probes 1 For aiding in infection control use only the Blue probe and Blue isolation chamber for Oral and Axillary temperature taking The Red probe and Red isolation chamber must only be used...

Page 8: ...ss again as needed 13 Eject the used cover into a bio waste container by pushing top button 14 After returning the probe to the probe well the temperature is stored for recall until the probe is once...

Page 9: ...ring use to indicate Direct mode operation 3 To exit Direct mode lock and return to normal operation again press and hold the Site and C F buttons at the same time for 4 seconds A long beep will be so...

Page 10: ...top half of the door upwards pressing firmly on the top of the door until the small tab on the main unit clicks into the catch on the battery door 7 Reinstall isolation chamber with probe attached VII...

Page 11: ...ectal Mode 10 14 seconds Direct Mode All Sites 60 120 seconds Typical times for switch to Direct Mode If no measurement site detected 60 seconds after pulling probe from probe well If temperature does...

Page 12: ...ontinuous Use Intended for hand held use Degree of Safety of Application in the Presence Not suitable for use in the presence of flammable anesthetic mixture with air oxygen or nitrous oxide Transport...

Page 13: ...mperature A Filac 3000 EZ EZA Electronic Thermometer should have a quick predict mode accuracy within 0 3 C of the calibrated water bath temperature The probe cable connector is designed to exceed 1 0...

Page 14: ...A Reorder No 505003 Complete Rectal Thermometer Includes electronic thermometer with Red Rectal isolation chamber and Red Rectal probe with 4 foot 1 2 m cord and global manual on CD Filac 3000 EZ Reor...

Page 15: ...ty of merchantability or fitness for a particular purpose or application other than as expressly set forth in the product labeling Section XII Electromagnetic Conformity Declaration The Filac 3000 Ele...

Page 16: ...ions it is recommended that the P STIM be powered from an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field EN 61000 4 8 per EN 60601 1 2 2001 3 A m 3 A m Power frequen...

Page 17: ...ce in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in...

Page 18: ...U S and internationally registered trademarks of Covidien AG TM Trademark of its respective owner Other brands are trademarks of a Covidien company 2012 Covidien Made in China Covidien llc 15 Hampshir...

Reviews: