To Order/Reorder/Replace device components and accessories, specify one or more of the following 

Reorder Numbers:

Probe Covers 

 

Case of 500 

Reorder No. 500500 

 

 

Case of 2,000  

Reorder No. 502000 

Note: 

Use of any other brand or style probe cover will result in erroneous temperature readings.

Complete Oral /Axillary Thermometer

Includes electronic thermometer with Blue - Oral/Axillary isolation chamber and Blue - Oral/Axillary probe, with 4-foot (1.2 m) cord, 
and global manual on CD
 

Filac 3000 EZ 

Reorder No. 504000  

 

Filac 3000 EZA  

Reorder No. 504003  

 

Filac 3000 AD 

Reorder No. 505000  

 

Filac 3000 ADA  

Reorder No. 505003  

Complete Rectal Thermometer

Includes electronic thermometer with Red - Rectal isolation chamber and Red - Rectal probe, with 4-foot (1.2 m) cord, and global 
manual on CD
 

Filac 3000 EZ 

Reorder No. 504005

 

Filac 3000 EZA 

Reorder No. 504008

 

Filac 3000 AD 

Reorder No. 505005

 

Filac 3000 AD 

Reorder No. 505008

Isolation Chamber

 

Blue - Oral/Axillary 

Reorder No. 500028

 

Red - Rectal 

Reorder No. 500038

Probe

 (with 4-foot standard cord) 

 

Blue - Oral/Axillary 

Reorder No. 500026

 

Red - Rectal 

Reorder No. 500036

Probe

 (with 9-foot standard cord) 

 

Blue - Oral/Axillary 

Reorder No. 500027

 

Red - Rectal 

Reorder No. 500037

Calibration Plug

 

Reorder No. 500099

Mounting Base for Wall

 

Reorder No. 500046

Mounting Base for Rolling Stand

 

Reorder No. 500047

Mounting Base with Pole Clamp

 

Reorder No. 500048

Rolling Stand

 

Reorder No. 303059

Rolling Stand Basket

 

Reorder No. 8884813711

Summary of Contents for Filac 3000 EZ

Page 1: ...Table of Contents Filac TM 3000 EZ EZA Electronic Thermometer Operating Manual...

Page 2: ...Filac 3000 EZ EZA Electronic Thermometer Operating Manual...

Page 3: ...ectal Temperature Taking 5 Direct Mode 6 Direct Mode Lock 6 Recall Last Temperature 6 VI Cleaning and Sterilization 6 VII Battery Replacement Installation 7 VIII Troubleshooting 7 IX Specifications 8...

Page 4: ...urement and Regulation Plenum Press NY 1982 p 81 87 II General Information 1 The Filac 3000 EZ EZA Electronic Thermometer is a fast highly accurate and easy to use clinical instrument for measuring pa...

Page 5: ...not open unit No user serviceable parts inside Opening of device may affect calibration and voids warranty 11 Disposal of used probe covers must be performed in accordance with current medical practic...

Page 6: ...limitations 10 95 Temperature limitations 13 F 25 C 131 F 55 C Follow instructions for use This manual must be read prior to use of the thermometer Symbol appears blue on device Non ionizing electroma...

Page 7: ...mbersand Probes 1 For aiding in infection control use only the Blue probe and Blue isolation chamber for Oral and Axillary temperature taking The Red probe and Red isolation chamber must only be used...

Page 8: ...ss again as needed 13 Eject the used cover into a bio waste container by pushing top button 14 After returning the probe to the probe well the temperature is stored for recall until the probe is once...

Page 9: ...ring use to indicate Direct mode operation 3 To exit Direct mode lock and return to normal operation again press and hold the Site and C F buttons at the same time for 4 seconds A long beep will be so...

Page 10: ...top half of the door upwards pressing firmly on the top of the door until the small tab on the main unit clicks into the catch on the battery door 7 Reinstall isolation chamber with probe attached VII...

Page 11: ...ectal Mode 10 14 seconds Direct Mode All Sites 60 120 seconds Typical times for switch to Direct Mode If no measurement site detected 60 seconds after pulling probe from probe well If temperature does...

Page 12: ...ontinuous Use Intended for hand held use Degree of Safety of Application in the Presence Not suitable for use in the presence of flammable anesthetic mixture with air oxygen or nitrous oxide Transport...

Page 13: ...mperature A Filac 3000 EZ EZA Electronic Thermometer should have a quick predict mode accuracy within 0 3 C of the calibrated water bath temperature The probe cable connector is designed to exceed 1 0...

Page 14: ...A Reorder No 505003 Complete Rectal Thermometer Includes electronic thermometer with Red Rectal isolation chamber and Red Rectal probe with 4 foot 1 2 m cord and global manual on CD Filac 3000 EZ Reor...

Page 15: ...ty of merchantability or fitness for a particular purpose or application other than as expressly set forth in the product labeling Section XII Electromagnetic Conformity Declaration The Filac 3000 Ele...

Page 16: ...ions it is recommended that the P STIM be powered from an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field EN 61000 4 8 per EN 60601 1 2 2001 3 A m 3 A m Power frequen...

Page 17: ...ce in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in...

Page 18: ...U S and internationally registered trademarks of Covidien AG TM Trademark of its respective owner Other brands are trademarks of a Covidien company 2012 Covidien Made in China Covidien llc 15 Hampshir...

Reviews: