LEMCOM CANopen®
– User manual
Detailed
description of CANopen objects
COVAL
– LMCOP-EN-A-1155UM0068
45/49
12.33
210Ch – State of blue customizable LED
Various operating modes are available for the blue LED on the front of LEMCOM modules:
MODE
Byte 0
Detailed operation
BL 1
00h
ASC CTRL FAULT INFO:
LED ON if ASC option is activated / Flashing if control fault (continuous suction) /
otherwise OFF
BL 2
01h
ASC ACTIVE:
LED ON if ASC option is activated / otherwise OFF
BL 3
02h
CONTROL RUNNING:
LED ON during control phase / otherwise OFF
BL 4
03h
CONTROL FAULT:
LED flashing upon control fault (continuous suction) / otherwise OFF
BL 5
04h
MAINTENANCE AFTER 30 MILLION CYCLES:
LED ON if Vacuum Cycles > 30 MCycles / otherwise OFF
Table 16
– State of blue customizable LED
SDO command:
CAN-ID
(600h+ID)
620h
Command
2Fh
Object L
0Ch
Object H
21h
Subindex
Module no.+1
Byte 0
00h
Byte 1
00h
Byte 2
00h
Byte 3
00h
The
subindex
is used to define the module to be set (from 1 to 16):
- Subindex = 0x01
set BLUE_LED_MODE on master module (address #0)
- Subindex = 0x02
set BLUE_LED_MODE on secondary module at address #1
-
…
- Subindex = 0x10
set BLUE_LED_MODE on secondary module at address #15
Byte 0
is used to define the operating mode of the blue LED according to the above table. Mode BL1
is the default operating mode.